Section 4 - Pump Start Up And Operation - Goulds Pumps VIT Installation, Operation And Maintenance Instructions

Vertical industrial turbine pumps
Table of Contents

Advertisement

9. Install the bottom of the flexible coupling to the top
of the drive shaft.
10. Attach a sling to the lifting lugs of driver and hoist
the driver up. Inspect the mounting surface, register
and clean these surfaces thoroughly. If any burrs
are found, remove burrs with a smooth mill file,
cleaning thoroughly afterward. Temporarily attach
the top half of the flexible coupling to the motor
shaft.
11. Orient the motor conduit box in the required
position. Align the driver mounting holes with the
mating tapped holes on the discharge head. Lower
the driver until the registers engage and the
driver rests on the thrust pot assembly. Secure
driver with capscrews provided.
12. Secure the flexible coupling assembly.
13. Install the coupling guard.
14. Fill the oil reservoir with recommended oil.
Pump Startup and Operation – SECTION 4
Pump Startup and Operation – SECTION 4
PRE-START PROCEDURE
Consult the applicable manufacturer's instructions
for detailed information for the prime mover
(electric motor, engine or steam turbine), coupling,
driveshaft, gear driver. Prior to startup, check the
following:
1. Confirm that the following procedures
described in the "Installing the Drivers"
sections have been performed:
A. Wiring of Driver.
Figure 19 – Oil Lubricated Thrust Pot
ITEM
DESCRIPTION
1
Thrust pot body
2
Tube - oil retaining
3
Thrust bearing
4
Capscrew - head to thrust pot
5
Washer - head to thrust pot
6
Hex Nut - head to thrust pot
7
Roller bearing
8
Bearing seat
9
Allen head screw
10
Capscrew - motor adapter to motor or thrust pot
11
Washer - motor adapter to motor or thrust pot
12
Gasket
13
Capcsrew
14
Non-reverse pin
15
Socket head screw
16
Gib key
17
Adjusting nut
18
Coupling guard
19
Setscrew
24
B. Driver must rotate counterclockwise (CCW)
when viewed from above.
Do not check motor rotation unless motor
WARNING
is bolted to pump and drive coupling is
removed.
Be sure to remove all the hand tools and to install the
coupling guards around all exposed shafts and couplings
before start up of the pump. Failure to comply may
result in sever personnel injury or death.
C. Check alignment of pump and driver.
D. Impeller adjustment has been made.
E. Mechanical seal lock collar is attached to shaft.
ITEM
DESCRIPTION
20
Flexible shaft coupling
21
Gib key
22
Key (motor shaft)
23
Setscrew
24
Round head screw for coupling guard
25
Washer coupling guard
26
Motor adapter
27
Capscrew - adjusting nut
28
Washer - adjusting nut
29
Retaining ring
30
Hollow shaft clutch
31
Non-reverse plate
32
Pipe plug - oil filling
33
Retaining ring
34
Hollow shaft
35
Shaft sleeve
36
Sight gauge
37
Pipe plug - oil drain