Attach Anti-Tip Bracket - Fisher & Paykel ACTIVESMART RS90A Installation Manual

Integrated slide-in refrigerator
Hide thumbs Also See for ACTIVESMART RS90A:
Table of Contents

Advertisement

IMPORTANT!
Ensure the refrigerator door is closed when rolling into cabinetry.
DO NOT attempt to open the door until refrigerator is fully installed.
The anti-tip bracket and fittings supplied must be fitted to the wall of finished enclosure
to withstand 220 lbs (100kg) load.
Ensure that anti-tip bracket is installed correctly to prevent the refrigerator tipping
forward when door is open.
Project horizontally from the bottom end of the alcove
1
return towards the back wall (A).
– This will locate the contact surface between the
bracket and the top surface at the back end of
the refrigerator.
Mark the screw locations of the anti-tip bracket on the
2
wall based on the most central wall stud (B).
– If there are no wall studs, the bracket can be
installed to solid brick walls with masonry plugs.
(However, not recommended to be used on
perforated brick or hollow concrete bricks).
B
Drill screw holes to the marked locations.
3
9

 ATTACH ANTI-TIP BRACKET

For wooden/plaster board wall installation:
4
Fix the bracket to the wall with 10-12x35mm pan
head screws (4x), and screw tightly (C).
A
Bracket
For solid wall installation:
5
Hammer 10x30mm masonry plugs (x4) into the
wall until flush.
Fix the bracket to the wall with 10-12x35mm pan
head screws (4x), and screw tightly (D).
WARNING!
Read the following reminders before fastening with masonry plugs and/or screws:
Ensure the screws avoid electrical, gas and water conduits.
Ensure the surface of the bracket is fastened to withstands a 220.5 pound (100kg) load.
Ensure light-weight masonry material such as cinder block and new concrete (no curing
time) are not used in installation.
Do not use metallic materials that may corrode, stain and/or damage the enclosure.
C
D
IMPORTANT!
When positioning the refrigerator in the cabinetry,
ensure that the bracket overlaps the refrigerator by a
minimum 60mm for a secure hold.
2 3/8" min.
(60mm) overlap
If the minimum 60mm overlap cannot be achieved,
install a solid spacer to the wall stud behind the bracket.
2 3/8" min.
(60mm) overlap
Bracket
Bracket
Spacer
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Activesmart rs90au

Table of Contents