7.2

Solving problems

Defect
It will not turn
·
on.
It does not
·
activate the
electromagnet
(turnstile cannot
be locked).
The arm does not
·
remain in the
correct position.
It does not lock
·
in the first
tooth.
Possible causes
The power supply's input
·
cable is not connected
properly
The circuit breaker is off.
·
The cable is broken or the
·
distance between the
electromagnet and the
locking device is
maladjusted.
There is wear, dirt, a
·
broken spring or lack of
lubrication in the sphere
base.
The distance between the
·
electromagnet and the
locking device is
maladjusted.
Action
Check the cables
·
and the fuse.
Adjust the
·
electromagnet or
forward the
equipment to the
Technical
Assistance.
Request a
·
replacement for
the faulty part or
forward the
equipment to the
Technical
Assistance.
Adjust the
·
electromagnet or
forward the
equipment to the
Technical
Assistance.