11. EXPLANATION OF COMPONENTS

11.15 FUSIBLE LINK

If the starting motor will not rotate when the starting switch is turned
ON, a possible cause is disconnection of wire-type fusible link
the battery room door on the left side of the machine body to inspect the
fusible link and, if necessary, replace it.
REMARK
A fusible link refers to the large-sized fuse wiring installed in the high
current flow portion of the circuit to protect electrical components and
wiring from burning, similar to an ordinary fuse.

11.16 CONTROLLERS

A combined pump and engine controller is provided.
NOTICE
Never splash or spill water, mud or drink over the controllers as
this may cause a fault.
If a fault occurs in the controller, do not attempt repair, but con-
sult your Komatsu distributor.

11.17 TOOL BOX

This is used for keeping the tools.
11.18 REFUELLING PUMP (Option)
• Do not bring fire or sparks near the fuel.
1.
When the machine is operated on sites with no fuel container and
pump, the machine may be refuelled using the refuelling pump
fitted) from fuel barrels.
The refuelling pump is located next to batteries at the front right hand
side of the machine.
2.
Place the fuel hose
placed next to the machine.
3.
Switch on refuelling pump using switch
when adding fuel, never let the fuel overflow. This may cause a fires.
Notes
This pump is protected bay fuse
fuse (10A).
Ensure strainer on hose end is clean.
2-36
WARNING
, which is stored in tray
on the pump assembly
. If pump fails to function check
. Open
(if
into the fuel barrel
ON
OFF