4.1. GasClam 2 Date and Time

The GasClam 2 time and date is shown in green and the PC time and date is shown in blue. To update the
GasClam 2 time click the "Set Time" button. Note. The GasClam 2 time is likely to differ from the PC time if it was
set on a different computer than is currently being used.

4.2. Save Setting Changes

After making any changes in the "Logging Setup" window it is important
to click the "Write settings to GasClam 2" button to save all changes.
If the write is successful a message "Settings written successfully" will
appear. Click OK to continue.
Without clicking the "Write settings to GasClam 2" all the changes that
have been made will be disregarded.

4.3. Manual Battery Selection

The Alk-Mn Duracell and NiMH rechargeable batteries have similar nominal
voltages, if either are fitted the GasClam 2 automatically selects the NiMH
battery.
However, when Alk-Mn batteries are fitted the power supply should be
changed manually, Alk-Mn batteries have different performance
characteristics.
After saving the power supply cannot be change until after a hard reset (the
GasClam 2 is without power for more than 10s).

4.4. GasClam 2 Name

Each GasClam 2 can be assigned a "friendly" name. This is useful if more than
one GasClam 2 is being used on a site or more sites are being monitored. For
example, the named could represent the site and borehole number.
Only alphabetic characters, numbers and "-" or "_" can be used.
The "friendly" name is also used in the filename for the data downloaded from
each GasClam 2 helping to identify from which location the data was obtained.

4.5. Erasing Logging Data

To erase all the logging data from the GasClam 2 click the "Erase GasClam 2
Logging Data" button, you will be prompted to confirm the action.
Important: This process erases stored data permanently. Make sure you
have downloaded the data from the GasClam 2 onto your computer (see
Download section).
Unrivalled
Detection.
ionscience.com

Advertisement

Table of Contents
loading

Table of Contents