Parameter Data/Demand Data; Inversion Of The Inputs - Balluff BNI IOL-309-002-Z019 User Manual

Io-link 1.1 sensor/actuator hub with extension port
Hide thumbs Also See for BNI IOL-309-002-Z019:
Table of Contents

Advertisement

5
Configuration: "Extension Off"
5.4. Parameter
Data/Demand
Data
Parameter
Data/Demand
Data
www.balluff.com
DPP
SPDU
Index
Index
Sub-
index
07
hex
08
hex
09
hex
0A
hex
0B
hex
10
0
hex
11
0
hex
12
0
hex
13
0
hex
14
0
hex
15
0
hex
16
0
hex
17
0
hex
0
18hex
DPP
SPDU
Index
Index
Subindex
40
0
hex

Inversion of the inputs

64
1-8
41
0
hex
65
1-8
42
0
hex
66
1-8
44
0
hex
68
1-16
45
0
hex
69
1-8
54
hex
0
84
55
hex
0
85
Parameter
Data
width
Vendor ID
2 bytes
Device ID
3 bytes
Vendor name
8 bytes
Vendor text
16 bytes
Product
20/24
name
bytes
Product ID
7 bytes
Product text
16 bytes
Serial number
16 bytes
Hardware
revision
Firmware
revision
Application-
32 bytes
specific tag
Parameter
Data width
1 byte
Config. In-/Output
1 byte
Safe state on Pin 4
2 bytes
Voltage monitoring
2 bytes
Output monitoring
1 byte
Serial number
16 bytes
Extension port
1 byte
Access
Default value
rights
0378
hex
0x05 0B 10
BALLUFF
www.balluff.com
BNI IOL-309-002-Z019
BNI0093
sensor/actuator hub M8
0
hex
0
hex
Access rights
Read/write
Read / Write
Read/write
Read
Read
Read/write
Read/write
Default
Value
0
hex
0
hex
0
hex
-
-
16x00
hex
-
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bni iol-102-002-z019Bni0099

Table of Contents