Owner’s Manual Models: S2Q-PV, S5Q-PV, S5Q-PV-ASPL Powered by 425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1 t. (+1) 519.763.1032 • tf. (+1) 800.265.7246 (US and Canada only) t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069 e-mail: info@viqua.com www.viqua.com...
Page 2
• VIQUA replacement lamps undergo rigorous performance testing and strict quality control processes to ensure that the safety and performance certifications of the original equipment are not compromised. So, you can see that it's simply not worth the risk! Insist on genuine VIQUA replacement lamps.
Safety Information Section 1 Safety Information These are the original instructions. Please read this entire manual before operating this equipment. Pay attention to all danger, warning, and caution statements in this manual. Failure to do so could result in serious personal injury or damage to the equipment.
Safety Information WA R N I N G • During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 °C) and potentially lead to scalding. It is recommended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time. To eliminate this condition, a temperature management valve can be installed at the outlet of your UV system.
Spring SP008 Used on all systems Chamber Used on all systems Connector base 270276 Used on all systems QS-330 S2Q-PV Open-Ended 214 fused quartz sleeves with fire polished ends QS-463 S5Q-PV-ASPL/S5Q-PV O-ring 410867-R Used on all systems Retaining nut RN-001...
Page 6
Installation of UV Disinfection System Section 3 Installation of UV Disinfection System C A U T I O N Electronic controller must be connected to a Ground Fault Protected Circuit (GFCI) receptacle. Ensure green ground wire ring terminal is securely fastened to ground stud on UV chamber.s The disinfection system is designed to be mounted either horizontally or vertically at the point-of-use or point-of-entry depending on the specific flow rate of the unit.
Maintenance Procedure: 1. For shipping purposes, the UV lamp is shipped in a separate cardboard tube. Carefully remove the UV lamp from the shipping tube being careful not to touch the “glass” portion with your fingers. Insert the UV lamp into the quartz sleeve and chamber making sure the connection end is inserted last.
Page 8
Maintenance 4.1 Replacing UV Lamp N O T I C E Do not use water during replacement of UV lamp. Lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000 hours of continuous operation (approximately one year) in order to ensure adequate disinfection.
Page 9
Maintenance 4.2 Cleaning and Replacing Quartz Sleeve Note: Minerals in the water slowly form a coating on the lamp sleeve. This coating must be removed because it reduces the amount of UV light reaching the water, thereby reducing disinfection performance. If the sleeve can not be cleaned, it must be replaced.
3. Once the connections are made secure the wires with the terminal screws and plug the connector back onto the ballast Alarm side. Section 5 Specifications Model S2Q-PV S5Q-PV S5Q-PV-ASPL US Public Health 16mJ/cm 5 gpm (19 lpm) (0.9 m /hr) 11 gpm (42 lpm) (2.5 m...
VIQUA warrants the electrical (controller) and hardware components to be free from defects in material and workmanship for a period of three (3) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty.