4
Installation > Installation Procedure
15)
Open the guide, and install the 2 screws.
• 2 Screws (Binding; M4x8)
x2
16)
Secure the Left Rear Cover and the Buffer Pass Unit together.
• 1 Screw (TP; M3x16)
4
Installation > Installation Procedure
17)
Close the guide.
18)
Close the Front Cover.
19)
Connect the harness to the host machine, and install the Reuse Band.
20)
Connect the 2 connectors, and route the harness along the Harness Guide.
F-4-20
F-4-21
4-8
Reuse Band
F-4-22
x2
F-4-23
4-8