B15
B16
B17
B18
B19
B20
<wspec [–] [0] digit[[.]digit]>
<CR>
<LF>
70
520 Installation Manual
Configuration
=00 (not used)
=01 if secondary DSPDIV=1
=10 if secondary DSPDIV=2
=11 if secondary DSPDIV=5
Configuration
N/A
Configuration
=000 if current DECPNT=8888800
=001 if current DECPNT=8888880
=010 if current DECPNT=8888888
=011 if current DECPNT=888888.8
=100 if current DECPNT=88888.88
=101 if current DECPNT=8888.888
=110 if current DECPNT=888.8888
=111 if current DECPNT=88.88888
Configuration
=000 if primary DECPNT=8888800
=001 if primary DECPNT=8888880
=010 if primary DECPNT=8888888
=011 if primary DECPNT=888888.8
=100 if primary DECPNT=88888.88
=101 if primary DECPNT=8888.888
=110 if primary DECPNT=888.8888
=111 if primary DECPNT=88.88888
Configuration
=000 if secondary DECPNT=8888800
=001 if secondary DECPNT=8888880
=010 if secondary DECPNT=8888888
=011 if secondary DECPNT=888888.8
=100 if secondary DECPNT=88888.88
=101 if secondary DECPNT=8888.888
=110 if secondary DECPNT=888.8888
=111 if secondary DECPNT=88.88888
Configuration
N/A
Scale weight
Weight for the source scale. wspec is defined as follows:
wspec indicates whether the weight is the current displayed weight
[–] Enter a minus sign (–) to include sign for negative values.
[0] Enter a zero (0) to display leading zeroes.
digit[[.]digit]
—
Carriage return
—
Line feed
Table 13-5. Custom Stream Format Identifiers (Continued)
(W,w), gross (G,g), net (N,n), or tare (T,t) weight. Upper-case
letters specify right-justified weights; lower-case are left-justified.
Optional /P, /S, or /T suffixes can be added before the ending
delimiter (>) to specify weight display in primary (/P) or secondary
(/S) units.
The first digit indicates the field width in characters. Decimal point
only indicates floating decimal; decimal point with following digit
indicates fixed decimal with n digits to the right of the decimal.