10.1.5

Normal Mode Commands

The normal mode commands (see Table 10-13) transmit data to the EDP port on demand. The SX command is
valid only in normal operating mode; all other commands are valid in either setup or normal mode.
Command
CONSNUM Set consecutive number
UID
Set unit ID
SD
Set date
ST
Set time
SX
Start EDP or PRN streaming
EX
Stop EDP or PRN streaming
DX
Start streaming raw A/D counts
RS
Reset system
XA
Transmit accumulator value
XC
Transmit count
XG
Transmit gross weight in displayed units
XN
Transmit net weight in displayed units
XT
Transmit tare weight in displayed units
XG2
Transmit gross weight in non-displayed units
XN2
Transmit net weight in non-displayed units
XT2
Transmit tare weight in non-displayed units
XE
Query system error conditions
Description
Table 10-13. Normal Mode EDP Commands
Response Format
0–9 999 999
nnnnnnn (up to seven characters)
MMDDYY, DDMMYY, YYMMDD (enter using DATEFMT
specified)
hhmm (enter using 24-hour format)
OK or ?? The respective port for EDP.STREAM or
PRN.STREAM must be set to LFT or IND to use these.
nnnnnn UU
where nnnnnn is the weight value, UU is the units.
nnnnn
See Section 13.3 on page 66 for detailed information about
the XE command response format.
EDP Commands