L M T S E R I E S | M A G N E TO S T R I C T I V E L E V E L T R A N S M I T T E R | O I/ L M T 1 0 0/ 2 0 0 - E N R E V. B
For example use the tank in 8 6 2 1-2, where the Diameter is
1000 mm, Length is 2500 mm, Input Unit is mm, Output type is
Volume, Output unit is liters
Point #
00
01
Input Value
0
100
<In> (mm)
Output
0
102.19
Value
<Out> (lit)
Using linearization tables
STEP 1:
Log in as an "Advanced user by pressing
STEP 2:
Press
to navigate to Device Setup menu
Press
to Select/Enter the Device Setup menu
STEP 3:
Press
to navigate to Linearization submenu
Press
to Select/Enter the Linearization menu
IMPORTANT NOTE
All parameters in the following section are edited the same
unless otherwise stated***
02
03
04
200
800
900
279.56
1683.94
1861.31
1963.5
Configuring Setup
STEP 1:
Press
or
Press
to Select/enter into the Linearization setup menu
20
1000
STEP 2:
Press
to Select/enter into the Table State menu
STEP 3:
Press
to edit the Table State
STEP 4:
Press
or
Press
to apply the highlighted action
to highlight setup
to highlight an action
39