L M T S E R I E S | M A G N E TO S T R I C T I V E L E V E L T R A N S M I T T E R | O I/ L M T 1 0 0/ 2 0 0 - E N R E V. B
Managing horizontal scales of the waveform
STEP 1:
Press
to scroll the cursor to the offset setting
Press
key to increase the horizontal offset to start
displaying the signal from a point further down the length of
the probe
STEP 2:
Press
to increase the horizontal scale or
reduce it
IMPORTANT NOTE
• Notice that if the scale selected covers more than the length
of the probe then the navigation to larger scale will be
rejected because the selected one already covers everything
that is to display
• Notice that after reaching the upper scale pressing the
key will rollover to the lowest scale
Managing the horizontal offset of the waveform
STEP 1:
Press
to scroll the cursor to the offset setting
Press
key to increase the horizontal offset to start
displaying the signal from a point further down the length of
the probe
STEP 2:
Press
to increase the horizontal offset or
reduce it
to
IMPORTANT NOTE
• Notice that if with the selected offset the screen covers more
than the length of the probe then the navigation to larger
offset will be rejected because the selected one already
covers everything that is to display
57