Screen
2 Setup input
EMU4-HM1-MB, EMU4-PX4
2-1.
(1) In 2-1, Push the ▲ or ▼ key , and move the cursor to the "1 Input".
[I/O]
(2) Push the
1
Input
(3) 2-2 will be displayed.
2 OP.Time
3 Output
2-2.
(1) Push the + or - key , and select the input method.
[Input]
[Input]
(Non/ Contact /Pulse)
Non
Non
(2) Push the
[1]
[1]
(3) Transition to the following screen by the model and setting input method.
[Non] setting
Model:EMU4-HM1-MB → To 2-1
EMU4-PX4 only
Model:EMU4-PX4 → To 2-5
[Pulse] setting → To 2-3
[Contact] setting → To 2-4
2-3.
(1) Push the ▲
[CONV.Rate]
[CONV.Rate]
and unit.
1.000
1.000
(2) Push the
[Unit]
[Unit]
Non
Non
[1]
[1]
(3) Transition to the following screen by the model.
Model:EMU4-HM1-MB → To 2-1
EMU4-PX4 only
Model:EMU4-PX4 → To 2-5
2-4.
(1) Push the + or - key, and select thereset mode.
[ResetMode]
[ResetMode]
(2) Push the
Auto
Auto
(3) Transition to the following screen by the model.
[1]
[1]
Model:EMU4-HM1-MB → To 2-1
Model:EMU4-PX4 → To 2-5
EMU4-PX4 only
2-5.
(1) Push the +
(Non/ Contact /Pulse)
[Input]
Non
(2) Push the
(3) Transition to the following screen by the setting input method.
[2]
[Non] setting → To 2-8
[Pulse] setting → To 2-6
[Contact] setting → To 2-7
2-6.
(1) Push the ▲ ▼ + - key, and change the "CONV.Rate" value
and unit.
[CONV.Rate]
1.000
(2) Push the
[Unit]
(3) 2-8 will be displayed.
Non
[2]
2-7.
(1) Push the + or - key, and select thereset mode.
[ResetMode]
(2) Push the
Auto
(3) 2-8 will be displayed.
[2]
2-8.
(1) Push the +
[Input]
(Non/ Contact /Pulse)
Non
(2) Push the
[3]
(3) Transition to the following screen by the setting input method.
[Non] setting → To 2-11
[Pulse] setting → To 2-9
[Contact] setting → To 2-10
2-9.
(1) Push the ▲ ▼
[CONV.Rate]
and unit.
1.000
(2) Push the
[Unit]
Non
[3]
(3) 2-11 will be displayed.
2-10.
(1) Push the +
[ResetMode]
(2) Push the
Auto
(3) 2-11 will be displayed.
[3]
2-11.
(1) Push the +
(Non/ Contact /Pulse)
[Input]
Non
(2) Push the
(3) Transition to the following screen by the setting input method.
[4]
[Non] setting → To 2-1
[Pulse] setting → To 2-12
[Contact] setting → To 2-13
2-12.
(1) Push the ▲ ▼ + - key, and change the "CONV.Rate" value
[CONV.Rate]
and unit.
1.000
(2) Push the
[Unit]
Non
[4]
(3) 2-1 will be displayed.
2-13.
(1) Push the + or - key, and select thereset mode.
[ResetMode]
(2) Push the
Auto
(3) 2-1 will be displayed.
[4]
Operation
/ Phase key.
/ Phase key.
▼ +
- key, and change the "CONV.Rate" value
/ Phase key, and confirm the setting value.
/ Phase key.
or -
key , and select the input method.
/ Phase key.
/ Phase key, and confirm the setting value.
/ Phase key.
or
- key , and select the input method.
/ Phase key.
+ - key, and change the "CONV.Rate" value
/ Phase key, and confirm the setting value.
or - key, and select thereset mode.
/ Phase key.
or - key , and select the input method.
/ Phase key.
/ Phase key, and confirm the setting value.
/ Phase key.
<EMU4-HM1-MB>
[Input]:Non⇔Contact⇔Pulse⇔
<EMU4-PX4>
[Input]:Pulse⇔Contact⇔Non⇔
[CONV.Rate]:0.001~10000(1.000)
[Unit]:Non⇔Wh⇔kWh⇔MWh⇔J⇔m
[ResetMode]:Auto⇔Hold⇔
Auto...Contact input state is reset automaticaly when
Hold...Contact input state is hold until contact input
- 9 -
Note
2
⇔m
kL⇔sec⇔min⇔hour⇔個⇔台⇔g⇔kg⇔t⇔
¥⇔$⇔
contact input is less.
released even thought contact input is less.
(For information about how to release of the
contact input, please refer to the instruction
manual (Detailed edition))