Mitsubishi Electric EMU4-D65 Instruction Manual page 7

Display unit
Hide thumbs Also See for EMU4-D65:

Advertisement

Screen
11-3.
(1) Push the ▲ ▼ + - key, and change the Ior difference converted
[DIF.Ior]
reference value.
(2) Push the
0.00 mA
(3) 11-1 will be displayed.
12 Setup the AD Converted
12-1.
(1) In 12-1, push the ▲ or ▼ key, and move the cursor to the
[Measure]
"11 AD CONV.".
9 SimpleMEA
(2) Push the
10DIF.CONV.
11AD CONV.
(3) 12-2 will be displayed.
12-2.
(1) Push the
[AD CONV.]
(2) Push the
On
(3) Transition to the following screen by the setting AD CONV.([On]/[Off])
[1]
[On] setting → To 12-3
[Off] setting → To 12-6
12-3.
(1) Push the
[Range]
(2) Push the
Current
(3) 12-4 will be displayed.
[1]
12-4.
(1) Push the ▲ ▼ + - key, and change the number of moving
[Moving
average.
average]
(2) Push the
001 times
[1]
(3) 12-5 will be displayed.
12-5.
(1) Push the ▲ ▼ + - key, and change the upper limit, lower limit,
[Scaling]
and unit.
Upp.: 04095
(2) Push the
Low.: 00000
Unit:Non
[1]
(3) 12-6 will be displayed.
12-6.
(1) Push the
[AD CONV.]
(2) Push the
On
(3) Transition to the following screen by the setting AD CONV.([On]/[Off])
[2]
[On] setting → To 12-7
[Off] setting → To 12-10
12-7.
(1) Push the
[Range]
(2) Push the
Current
(3) 12-8 will be displayed.
[2]
12-8.
(1) Push the ▲ ▼ + - key, and change the number of moving
[Moving
average.
average]
(2) Push the
001 times
[2]
(3) 12-9 will be displayed.
12-9.
(1) Push the ▲ ▼ + - key, and change the upper limit, lower limit,
[Scaling]
and unit.
Upp.: 04095
(2) Push the
Low.: 00000
Unit:Non
[2]
(3) 12-10 will be displayed.
12-10.
(1) Push the
[AD CONV.]
(2) Push the
On
(3) Transition to the following screen by the setting AD CONV.([On]/[Off])
[On] setting → To 12-11
[3]
[Off] setting → To 12-14
12-11.
(1) Push the
[Range]
(2) Push the
Current
(3) 12-12 will be displayed.
[3]
12-12.
(1) Push the ▲ ▼ + - key, and change the number of moving
[Moving
average.
average]
(2) Push the
001 times
[3]
(3) 12-13 will be displayed.
12-13.
(1) Push the ▲ ▼ + - key, and change the upper limit, lower limit,
[Scaling]
and unit.
Upp.: 04095
(2) Push the
Low.: 00000
Unit:Non
[3]
(3) 12-14 will be displayed.
12-14.
(1) Push the
[AD CONV.]
(2) Push the
On
(3) Transition to the following screen by the setting AD CONV.([On]/[Off])
[On] setting → To 12-15
[4]
[Off] setting → To 12-1
12-15.
(1) Push the
[Range]
(2) Push the
Current
(3) 12-16 will be displayed.
[4]
12-16.
(1) Push the ▲ ▼ +
[Moving
average.
average]
(2) Push the
001 times
[4]
(3) 12-17 will be displayed.
Operation
/ Phase key,and confirm the setting value.
EMU4-AX4 only
/ Phase key.
+ or - key, and select the AD converted([On]/[Off]).
/ Phase key, and confirm the setting value.
+ or - key, and select the input range.
/ Phase key, and confirm the setting value.
/ Phase key, and confirm the setting value.
/ Phase key, and confirm the setting value.
+ or - key, and select the AD converted([On]/[Off]).
/ Phase key, and confirm the setting value.
+ or - key, and select the input range.
/ Phase key, and confirm the setting value.
/ Phase key, and confirm the setting value.
/ Phase key, and confirm the setting value.
+ or - key, and select the AD converted([On]/[Off]).
/ Phase key, and confirm the setting value.
+ or - key, and select the input range.
/ Phase key, and confirm the setting value.
/ Phase key, and confirm the setting value.
/ Phase key, and confirm the setting value.
+ or - key, and select the AD converted([On]/[Off]).
/ Phase key, and confirm the setting value.
+ or - key, and select the input range.
/ Phase key, and confirm the setting value.
- key, and change the number of moving
/ Phase key, and confirm the setting value.
High SENS mode
[DIF.Ior]:0.00~100.00mA
Low SENS mode
[DIF.Ior]:0~1000mA
[AD CONV.]:Off⇔
AD CONV....The setting value is set inAD convert per
[Range]:Current⇔Voltage⇔
[Moving average]:001~100(001)
[Upp]:-32767~32767(4095)
[Low]:-32767~32767(0)
[Unit]:Non⇔A⇔mA⇔kA⇔V⇔kV⇔W⇔kW⇔MW⇔Hz⇔N⇔
- 7 -
Note
On
CH.
kN⇔Pa⇔kPa⇔MPa⇔C⇔deg⇔%⇔