Chapter 4: Setup Pages - Watlow EZ-ZONE RMC User Manual

Control module
Table of Contents

Advertisement

4

Chapter 4: Setup Pages

Control Module Setup Page Parameters
To navigate to the Setup Page using the RUI, follow
the steps below:
1. From the Home Page, press both the Up ¿ and
Down ¯ keys for six seconds. [``Ai] will appear
in the upper display and [`Set] will appear in the
lower display.
2. Press the Up ¿ or Down ¯ key to view available
menus.
3. Press the Advance Key
choice.
4. If a submenu exists (more than one instance), press
Note:
Some of these menus and parameters may not appear, depending on the controller's options. See model number
information in the Appendix for more information. If there is only one instance of a menu, no submenus will ap-
pear.
Note:
Some of the listed parameters may not be visible. Parameter visibility is dependent upon controller part number.
[``Ai]
[`Set] Analog Input Menu
[```1]
[``Ai] Analog Input 1 to 4
[`SEn] Sensor Type
[`Lin] TC Linearization
[`rt; L ] RTD Leads
[Unit] Units
[`S; L o] Scale Low
[`S; h i] Scale High
[`r; L o] Range Low
[`r; h i] Range High
[`P; E E] Process Error Enable
[`P; E L] Process Error Low Value
[``t; C ] Thermistor Curve
[``r; r ] Resistance Range
[`FiL] Filter
[`i; e r] Error Latching
[`dEC] Display Precision
[`i; C a] Calibration Offset **
[`Ain] Value **
[`i; E r] Error Status **
[``Pu]
[`Set] Process Value
[```1]
[``Pu] Process Value 1 to 4
[``Fn] Function
[SFn; A ] Source Function A
[`Si; A ] Source Instance A
[SFn; b ] Source Function B
[`Si; b ] Source Instance B
[`S2b] Source Zone B
[SFn; C ] Source Function C
[`Si; C ] Source Instance C
[`S2; C ] Source Zone C
** These parameters/prompts are available in these menus with firmware revisions 6 .0 and above .
®
Watl o w EZ-ZO N E
R M C Mo d u le
to enter the menu of
[SFn; D ] Source Function D
[`Si; D ] Source Instance D
[`S2; d ] Source Zone D
[SFn; E ] Source Function E
[`Si; E ] Source Instance E
[`S2; E ] Source Zone E
[``C; P ] Cross Over Point
[``C; b ] Cross Over Band
[P; u nt] Pressure Units
[A; u nt] Altitude Units
[`b; P r] Barometric Pressure
[`FiL] Filter
[`dio]
[`Set] Digital Input/Output Menu
[```1]
[`dio] Digital Input/Output 7 to 12
[`dir] Direction
[``Fn] Function
[``Fi] Function Instance
[`S2; A ] Source Zone A
[`o; C t] Control
[`o; t b] Time Base
[`o; L o] Low Power Scale
[`o; h i] High Power Scale
[`ACt]
[`Set] Action Menu
[```1]
[`ACt] Action 1 to 8
[``Fn] Function
[``Fi] Function Instance
[SFn; A ] Source Function A
[`Si; A ] Source Instance A
[`S2; A ] Source Zone A
[`LEu] Active Level
the Up ¿ or Down ¯ key to select and then press
the Advance Key
5. Press the Up ¿ or Down ¯ key to move through
available menu prompts.
6. Press the Infinity Key ˆ to move backwards
through the levels: parameter to submenu; submenu
to menu; menu to Home Page.
7. Press and hold the Infinity Key ˆ for two seconds to
return to the Home Page.
On the following pages, top level menus are identified
with a yellow background color.
[LiM]
[`Set] Limit Menu
[Loop]
[`Set] Control Loop Menu
5 6
to enter.
[```1]
[LiM] Limit 1 to 4
[`L; S D] Sides
[`L; h y] Hysteresis
[SP; L h] Set Point High Limit
[SP; L L] Set Point Low Limit
[`Lh; S ] High Set Point **
[`LL; S ] Low Set Point **
[SFn; A ] Source Function A **
[`Si; A ] Source Instance A **
[`S2; A ] Source Zone A **
[`l; C r] Clear Request **
[`l; s t] Status **
[```1]
[Loop] Control Loop 1 to 4
[SFn; A ] Source Function A
[`is; A ] Source Instance A
[`h; A g] Heat Algorithm
[`C; A g] Cool Algorithm
[`C; C r] Cool Output Curve
[`h; P b] Heat Proportional Band **
[`h; h y] Heat Hysteresis **
[`C; P b] Cool Proportional Band **
[`C; h y] Cool Hysteresis **
[``ti] Time Integral **
[``td] Time Derivative **
[``db] Dead Band **
®
[t; t Un] TRU-TUNE+
Enable
[t; b nd] TRU-TUNE+ Band
[`t; g n] TRU-TUNE+ Gain
[A; t SP] Autotune Set Point **
Chapter 4 Setup Pa ge

Advertisement

Table of Contents
loading

Table of Contents