  • Page 1 INSTALLATION MANUAL & OPERATION INSTRUCTIONS OVERHEAD CAR LIFT 2-POST LIFT AUTO HOIST APlusLift HW-10KOH...
  • Page 2 READ THIS MANUAL COMPLETELY BEFORE INSTALLING LIFT!!! DISTRIBUTED BY: Songa Enterprises LLC 8512 122ND AVE NE #25 Kirkland WA 98033 E-mail: apluslift@gmail.com Text or Call: 425-429-2699 Website: www.apluslift.com READ THIS BEFORE INSTALLING THE LIFT! Improper installation can cause injury or damage! •...
  • Page 3 Caution Labeling Exemplification...
  • Page 4 TABLE OF CONTENTS INTRODUCTION INSTALLATION & OPERATION MAINTENANCE & SAFETY...
  • Page 5 1. Introduction BOLT BOX CONTENTS Part description POWER UNIT Hydraulic Tee Fitting Extended Fitting to cylinder 4.3 inch Overhead Safety limit Switch & 4 screws Overhead Safety Bar Nut for Overhead safety Bar M6x130 Anchor Bolts M18x160 Hex bolts, washers & nuts for beam mounting to M10x30 columns Hex bots, washers &...
  • Page 6 Fig.1, 2...
  • Page 7 Fig 3...
  • Page 8 2. INSTALLATION & OPERATION MANUAL Your lift is designed for many years of trouble-free service when properly installed & maintained. Please take the time to read this installation manual before proceeding. INSTALLATION TIPS • This Lift is built from very heavy metal material. User proper lifting techniques when lifting individual pieces. Use plenty of help when moving lift pieces.
  • Page 9 • Bolt Switch to the overhead beam. Assemble One end of the overhead safety shut off bar into Switch. Bolt the other end to the overhead beam. The wire from Switch will go to power unit. • Manually lift both carriages on each column about waist high. Let carriages down allowing them to set on the lift safety lock stops.
  • Page 10 hose cross the overhead beam. Run the hose down to the side of opposite column. Connect long hydraulic hose to 4.3 inches extended fitting in bottom of cylinder. DO NOT over tighten, as you will crack the fitting. Connect long hydraulic hose between the cylinders and let it lay inside the floor pan.
  • Page 11 HYDRAULIC FLUID • Remove the vent plug from the top of reservoir. You are going to fill the tank with fluid. Either AW 32 or 46 Hydraulic oil is good choice. We don't recommend the transmission fluid as it is too thin. The unit will hold approximately 2.64 gallons(10 liters) of fluid.
  • Page 12 FINAL ASSEMBLY • Check all bolts and nuts to make sure they are tight. Do not use an impact gun on concrete Anchors. • Check all fittings or leaks. If necessary, make sure the arm lock restraints are engaging properly and smoothly. If not, tap the main lock forward or backward as needed with a rubber mallet to insure proper engagement on all 4 gears with the arm restraint locks.
  • Page 13 • Push Up switch to raise lift (make sure arm restraints engage or stop and slightly move arm to allow gear to mesh) until tires clear floor. • Stop and check for secure contact on adapters and vehicle weight distribution. If secure raise to desired height. •...
  • Page 14 • If the safety latch in either column does not operate. Use the following procedure to adjust it. • Raise the lift until you can see the latch through the access hole in side of the column by removing the plastic cover. •...
  • Page 15 MAINTENANCE SCHEDULE The periodic Preventive Maintenance Schedule given is the suggested minimum requirements and minimum intervals; accumulated hours or monthly period which ever comes sooner. Periodic maintenance is to be performed on a daily, weekly, and yearly basis as given in the following paragraphs. WARNING!! Occupational Safety and Health Administration (OSHA) and the American National Standards Institute (ANSI) requires users to inspect lifting equipment at the start of every shift.
  • Page 16 • Grease rub blocks and column surface contacting rub blocks • Change the hydraulic fluid - good maintenance procedure makes it mandatory to keep hydraulic fluid clean. No hard fast rules can be established; - operating temperature, type of service, contamination levels, filtration, and chemical composition of fluid should be considered.