Setting Service (Service Uuid: 0X3010); Measurement Interval (Characteristics Uuid: 0X3011) - Omron 2JCIE-BL01 User Manual

Environment sensor
Table of Contents

Advertisement

2.2.

Setting Service (Service UUID: 0x3010)

Read and Write the settings of each sensor.
Characteristics
UUID
0x3011
0x3013
0x3014
0x3015
0x3016
0x3017
0x3018
0x3019
0x301A

2.2.1 Measurement interval (Characteristics UUID: 0x3011)

Specify measurement interval in seconds.(Common to all sensors)
Time information is cleared to zero (0) when changing the measurement interval, so it is necessary
to set the time again to start data recording.
Byte
0
Measurement interval
1
The possible recording period are shown in Table 16.
Table 16. Relationship between Measurement interval and possible recording period
Measurement interval
3600 sec
15
Table 14. List of Characteristics in Sensor Setting Service
Characteristics
Measurement interval
Temperature
Relative humidity
Ambient light
UV Index
Pressure
Sound noise
Discomfort index
Heat stroke
Table 15. Measurement interval format
Field
L
H
Recording period (hour)
1 sec
10 sec
30 sec
60 sec
300 sec
600 sec
Properties
R
W
N
I
Format
Unit:1 sec
UInt16
Range:1~3600 sec
Default:300 sec (0x012C)
Recording period (day)
7.4 hour
74 hour
222 hour
444 hour
2219 hour
4437 hour
26624 hour
2JCIE-BL01 Environment Sensor User's Manual (A278)
Byte
2
15
15
15
15
15
15
15
15
Contents
0.3 days
3.0 days
9.2 days
18 days
92 days
185 days
1109 days

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents