2.1.2 Latest page (Characteristics UUID: 0x3002)
The Latest page shows the latest page and row information of the memory as the progress status of
data recording.
The Central device can acquire the past memory data by referring to the difference between the
page information at the previous data retrieving and this latest page information.
Byte
0
1
UNIX TIME
2
3
4
Measurement interval
5
6
Latest page
7
8
Latest row
2JCIE-BL01 Environment Sensor User's Manual (A278)
Table 9. Latest page format
Field
Format
0
1
UInt32
2
3
L
UInt16
H
L
UInt16
H
UInt8
Contents
Created time of the latest page.
Unit:1 sec
Range:1970/1/1 0:00:01~2106/2/7 6:28:15
Unit:1 sec
Range:1~3600 sec
Range:0~2047
Range:0~12
10