2.2.6 Pressure (Characteristics UUID: 0x3017)

Barometric Pressure sensor related event settings.
Byte
0
Event Enable/Disable
1
Changing trend threshold
[rise/previous]
2
3
Changing trend threshold
[decline/previous]
4
5
Changing trend threshold
6
[rise/term]
7
Changing trend threshold
[decline/term]
8
9
Simple threshold
10
[upper limit]
11
Simple threshold
[lower limit]
12
Term for changing trend
13
(Number of Measurements)
14
Moving average number
2JCIE-BL01 Environment Sensor User's Manual (A278)
Table 21. Pressure format
Field
L
H
L
H
L
H
L
H
L
H
L
H
Format
Bit 7-6 : RFU
Bit 5 : Simple threshold [lower limit]
Bit 4 : Simple threshold [upper limit]
Bit 3 : Changing trend [decline/term]
UInt8
Bit 2 : Changing trend [rise/term]
Bit 1 : Changing trend [decline/previous]
Bit 0 : Changing trend [rise/previous]
Enable: 1, Disable: 0
Default:0x00
SInt16
SInt16
Unit:0.1 hPa
Range:0.1~200.0 hPa
Default:0x0032 (5.0 hPa)
SInt16
SInt16
Unit:0.1 hPa
SInt16
Range:700.0~1100.0 hPa
Default:0x2AF8 (1100.0 hPa)
Unit:0.1 hPa
SInt16
Range:700.0~1100.0 hPa
Default:0x1B58 (700.0 hPa)
Unit:1 count
UInt8
Range:1~8 count
Default:0x06 (6 count)
Unit:1 count
UInt8
Range:1~8 count
Default:0x01 (1 count)