This quick guide is a summary of the complete installation manual. The manual contains safety warnings and other explanations which must be taken into account. The installation manual can be downloaded by going WARNING to the "Downloads" section of Erreka website: http://www.erreka-automation.com Electrical Connections...
Page 2
Display indications LED Display Programmable Functions “N-L”: The system learning is not done. “CLN” the memory of the system is all cleaned/deleted. Press “UP+DOWN” for 5 seconds. “RUN”: The system is in normal “ME”: Motor operation error. performing. “LEA”: Enter learning mode and then “STP”: the motor stop in the middle of wait for learning instructions.
Page 3
Radio code programming Press and hold the RF-Learn for 1 Press A button for 5 seconds for double leaf Press B button for 5 seconds for single-gate second, the blue LED on the RF board gate Radio code programming installation. installation.
Page 4
Complete programming chart (1) LED Display Definition Parameter Mode Description Encoder/ Limit switch F1-1 Motor only 1. The factory setting is "F1-1". F1-2 Motor with limit switch F1-3 Motor with encoder F2-1 Number of operators Two Operators 1. The factory setting is "F2-1". F2-2 One Operator Maximum trapping force...
Page 5
Complete programming chart (2) LED Display Definition Parameter Mode Description 1. The factory setting is "FC-0". Photocell1 FC-0 FC-1 Photocell2 FD-0 1. The factory setting is "FD-0". FD-1 Buzzer Function FE-0 1. The factory setting is "FE-0". FE-1 Reverse Impulse for FF-0 1.