PCE Health and Fitness 5000H User Manual

PCE Health and Fitness 5000H User Manual

Coating thickness gauge

Advertisement

Quick Links

User Manual
PCE-CT 5000H Coating Thickness Gauge
User manuals in various languages (français,
italiano, español, português, nederlands, türk, polski,
русский, 中文) can be found by using our
product search on: www.pce-instruments.com
Last change: 6 September 2018
v1.0
© PCE Instruments

Advertisement

Table of Contents
loading

Summary of Contents for PCE Health and Fitness 5000H

  • Page 1 User Manual PCE-CT 5000H Coating Thickness Gauge User manuals in various languages (français, italiano, español, português, nederlands, türk, polski, русский, 中文) can be found by using our product search on: www.pce-instruments.com Last change: 6 September 2018 v1.0 © PCE Instruments...
  • Page 2: Table Of Contents

    Contents Safety notes ................... 1 Introductions ..................2 Features ........................... 2 Application ........................2 Principle of Measurement ....................2 Delivery contents ......................3 Device description ................3 Specifications ..................4 Use the Gauge ..................5 Replacing the Battery ....................... 5 Basic Measurement Step ....................
  • Page 3: Safety Notes

    Safety notes Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
  • Page 4: Introductions

    Introductions This compact gauge can be used for non-destructive coating thickness measurement of non- magnetic coatings, e.g. paint, enamel, chrome on steel, and insulating coatings, e.g. paint and anodizing coatings on non-ferrous metals. Features • 128* 128 dot matrix LCD display, standard menu operations; •...
  • Page 5: Delivery Contents

    Delivery contents 1 x PCE-CT 5000H thickness gauge 2 x Zero calibration plates (ferrous and non-ferrous) 5 x Calibration plates 2 x 1.5V AAA batteries 1 x USB cable 1 x PC-compatible software 1 x User manual 1 x Carrying case Device description 1.
  • Page 6: Specifications

    Specifications Probe Type F and Type N 0 ... 5000 μm / 0 ... 5 mm / 0 ... 196 mils Measuring range Type ± (2% + 1 μm) Measuring accuracy Type F 0 ... 99.9 μm: 0.1 μm, 100 ... 999 μm: 1 μm Resolution Type F >...
  • Page 7: Use The Gauge

    Use the Gauge If you use the gauge for the first time, please read the chapter 6 Factors Affecting Measurement Accuracy. Replacing the Battery Place the gauge upside down on a suitable surface, remove the screws from the battery compartment with a crosstip screwdriver, raise the lid of the compartment, remove battery, insert new battery according to the positive and negative poles and close the lid and fasten with screws.
  • Page 8: User Interface

    User Interface The gauge has a standard user interface for easy use. • Left Key a. To enter into menu mode from measure mode; b. Left button operations in menu mode (Including “Sure”, “Select”, “Delete”); • Right Key a. Right button operations in menu mode(Including “Cancel”, “Back”, “Exit”); b.
  • Page 9: Measure Mode (Only Support Single Mode)

    Measure Mode (Only Support Single Mode) Single measure mode - Place the probe on sample vertically and rapidly, and after one beep, raise it rapidly. Group Mode • Direct Group (DIR)-Be intended for quick occasional readings. In this mode, data are temporarily stored in RAM, it will be lost when power off.
  • Page 10: Probe Mode

    Probe Mode There are three probe modes: AUTO, MAG and EDDY. In AUTO mode, the probe can automatically determine the type of substrate measured. In MAG mode, the probe can only measure on magnetic substrates. In EDDY mode, the probe can only measure on non-ferrous metal substrates.
  • Page 11: High And Low Limit Alarm

    • Delete whole group readings (Tip: If in measure mode, hold the “UP Key” by one beep) a. Press “Left Key” once to enter menu mode (”Root” directory). b. Press “Up Key” or “Down Key” to activate “Delete Data” item, and press “Left Key” once to enter.
  • Page 12: Unit

    5.11 Unit User can select the shown unit (including µm, mm and mils) for the readings. Switch the unit as below. a. Press “Left Key” once to enter menu mode (”Root” directory). b. Press “Up Key” or “Down Key” to activate “Options” item, and press “Left Key” once to enter. c.
  • Page 13: Measurement Accuracy

    5.15 Measurement Accuracy Factors of affecting measurement accuracy, please reference the chapter 6 Factors Affecting Measurement Accuracy. Under normal use and careful calibration, all subsequent measurements will lie within the guaranteed measuring tolerance. When using the statistics programmer for obtaining a mean value it is advisable to place the probe several times at a typical measuring spot or at fixed measuring spot.
  • Page 14: Calibration

    The measured sample must correspond to the calibration sample in substrate material properties, curvature radius, or the more closely the measured sample matches the calibration sample, the more accurate the measuring. In addition, curvature radius should meet the minimum value as specified in the specifications.
  • Page 15 Multi-point Calibration a. In measure mode, press “CAL key” once to enter calibration mode. b. Zero calibration according to the previous chapter and then lay the calibration foil on an uncoated sample. c. Apply the probe and raise it after one beep. A reading will be shown. Press “Up Key” or “Down Key”...
  • Page 16: Troubleshooting

    Clear Calibration User can clear calibration to start new applications. When the values are still out of tolerance, the user should clear it. a. Press “Left Key” once to enter menu mode (”Root” directory). b. Press “Up Key” or “Down Key” to activate “Calibration” item, and press “Left Key” once to enter.
  • Page 17: Warranty

    Warranty You can read our warranty terms in our General Business Terms which you can find here: https://www.pce-instruments.com/english/terms. Disposal For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
  • Page 18 PCE Instruments contact information Germany France Spain PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 4 23, rue de Strasbourg Calle Mayor, 53 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel.