PRTxxEM series readers Operating Manual.doc 2018-08-21 1. GLOSSARY OF TERMS ................. 4 2. IMPORTANT NOTES ..................5 2.1. Compatibility Rules ........................... 5 2.2. About This Manual ..........................5 3. GENERAL DESCRIPTION ................5 3.1. Features ..............................6 3.1.1. General ..............................6 3.1.2.
Page 3
PRTxxEM series readers Operating Manual.doc 2018-08-21 5.7. Door Alarm ............................16 5.8. Tamper Alarm ............................. 17 5.9. Intruder Alarm ........................... 17 5.10. Duress Alarm ............................ 17 5.11. General Alarm ..........................17 5.12. Events Recording ........................... 17 5.13. Real Time Clock ..........................19 5.14.
XM-2 expander and/or second PRT series reader. RACS Interface The electrical interface and addressable protocol developed by Roger. This interface is implemented in access readers and controllers manufactured by Roger. The RACS interface uses two communication lines (CLK and DTA) and proprietary communication protocol capable to address up to 16 devices.
This program enables programming and maintenance of the PRT series reader which are equipped with serial communication interface. RogerISP Program This program enables firmware upgrade in access controllers and readers manufactured by Roger. 2 . I M P O R T A N T...
3.1.2. Terminal Mode (Online Mode) 26/32/32 reversed/34/42/66 bit Wiegand data formats Magstripe data format (ABA Track II emulation) RACS CLK/DTA (for communication with Roger controllers) RS232, EPSO protocol RS232, direct output of cards and keys ...
Wiegand 66bit Magstripe (ABA Track II emulation, also called Clock & Data) RACS CLKD/DTA (addressable format for communication with Roger controllers) RS232, EPSO protocol (transactional protocol, reader responses commands received from the host) RS232, cards and individual keys ...
PRTxxEM series readers Operating Manual.doc 2018-08-21 4.1.1. Wiegand Formats When using Wiegand transmission format, data is transmitted to the host via CLK and DTA lines. Depending on the selected version of the transmission format, the reader can send 26, 32, 34, 42 or 66 bits to the host. PIN can be transmitted as a whole (when # key is pressed ) or each digit separately –...
PRTxxEM series readers Operating Manual.doc 2018-08-21 4.1.4. RS232, EPSO Protocol (9600, N, 8, 1) When programmed to this protocol reader operates in transaction mode, i.e. responds only to external commands received through the RS232 port. The software developer or system integrator must incorporate EPSO protocol into the host device (usually PC or microcontroller) to communicate with the reader.
PRTxxEM series readers Operating Manual.doc 2018-08-21 4.2.2. Simple Standalone Mode The CLK and DTA lines may operate either as inputs or outputs. The function assigned to CLK or DTA line automatically defines whether this line will operate as output or input. If configured to be an output, the CLK or DTA line operates as an open collector line capable to sink up to 150 mA.
PRTxxEM series readers Operating Manual.doc 2018-08-21 switch reader between armed and disarmed modes, Programming they can have card and/or PIN. Note: All users can be programmed from RARC program as well. Note: MASTER and INSTALLER cards can be used as Programming Cards to start associated programming mode and to program reader based on multiple card readings method.
PRTxxEM series readers Operating Manual.doc 2018-08-21 example when Facility Code is defined as “xxxx1ABxxx” then every card which has the same pattern is accepted by the reader regardless of the fact that it is not registered individually in reader’s memory. The positions marked with x are not analyzed for compliance with Facility Code. 5.4.
Page 14
PRTxxEM series readers Operating Manual.doc 2018-08-21 Once accepted the reader grants you access (assuming that access is not disabled by option Access disabled when reader armed) and LED SYSTEM starts blinking When LED SYSTEM is blinking, once again present your TOGGLE card ...
Page 15
PRTxxEM series readers Operating Manual.doc 2018-08-21 When using proposed configuration the current arming mode of the reader is controlled by the alarm system (output line from alarm system controls reader’s arming state), as a result reader always operates in the same arming mode as alarm system. Using TOGGLE or TOGGLE LTD card/PIN users can “request”...
PRTxxEM series readers Operating Manual.doc 2018-08-21 5.5. D UNCTION By default the [F1]: Door Bell and [F2]: Light Bulb keys operate as door bell buttons. When pressed they produce continues sound generated by the internal buzzer and optionally can trigger the [47]: Door Bell output (if programmed).
PRTxxEM series readers Operating Manual.doc 2018-08-21 valid identifier disappears automatically after 3 minutes. Also, closing door immediately clears this alarm. Note: Modulation methods are used for both, the output line and for internal buzzer (if configured for alarm indication). Note: The Forced Entry and Door Ajar alarms can occur only if the reader operates with a door open sensor connected to the input with function [21]: Door Contact.
Page 18
PRTxxEM series readers Operating Manual.doc 2018-08-21 Access denied Access for the user (ID + name) has been denied Access denied – Facility Access has been denied for card with valid Facility Code Code Reader armed Reader has been switched to Armed mode by user (ID + name) Reader disarmed Reader has been switched to Disarmed mode by user...
PRTxxEM series readers Operating Manual.doc 2018-08-21 Duress Alarm Reader entered Duress Alarm state Unknown event Event code doesn’t fit any known event – error in data 5.13. R LOCK The reader is equipped with Real Time Clock (RTC) predefined for 100 year. This clock is used to append a time stamp to every event recorded by the reader.
PRTxxEM series readers Operating Manual.doc 2018-08-21 (00-99 sec./min.) counts down for unlimited period till moment when reader changes it arming mode. Duress Alarm 3 min Defines duration time for Duress Alarm. Programming timer to 00s makes that timer (00-99 sec./min.) counts down for unlimited period till moment when reader changes it arming mode.
PRTxxEM series readers Operating Manual.doc 2018-08-21 Acoustic Signals Signal Symbol Description One long signal Error - unknown identifier, access denied. Three short * * * Command successfully completed (OK signal). beeps Two short beeps Prompt signal, the reader is waiting for the next part of the command to be entered.
PRTxxEM series readers Operating Manual.doc 2018-08-21 Preparing the Reader for Standalone Mode (Offline mode) If the unit is dedicated for Standalone Mode (autonomic operation) then proceed with programming procedure: 1. Configure the reader to either Full or Simple Standalone Mode operating mode and program MASTER and INSTALLER cards and/or PIN-s (Memory Reset) 2.
PRTxxEM series readers Operating Manual.doc 2018-08-21 keypad located on secondary (slave) reader. The LED/buzzer signals occur simultaneously on both readers (primary and secondary). Both readers must have the same supply minus. It is not required to disconnect the XM-2 expander from system being currently programmed. 6.2.
Code Operating mode Description Online mode, RACS address ID=0 Online mode, RACS address ID=1 Reader operates as a slave unit connected to the Roger access controller. Online mode, RACS address ID=2 Online mode, RACS address ID=3 Online mode, RS232, PINs...
Page 25
PRTxxEM series readers Operating Manual.doc 2018-08-21 Online mode, RS232, PINs Reader is connected to the host through RS232 transmitted as whole numbers (9600,N,8,1) serial interface. Each key entry is buffered, once the [#] key is pressed reader transmits entire PIN code as a single number max 16 digits long.
Page 26
PRTxxEM series readers Operating Manual.doc 2018-08-21 PIN/keys transmission options Description Details 1-10 digits long PIN, Each key pressed is buffered in reader’s memory; with a press of a [#] transmitted key reader transmits entire PIN code. The PIN code is transmitted as a format BCD coded number.
PRTxxEM series readers Operating Manual.doc 2018-08-21 8 . I N S T A L L E R R O G R A M M I N G Use this mode to configure various functionalities of the reader. Alternatively all Installer Programming settings can be entered with RARC software after connection of reader to computer.
Page 29
PRTxxEM series readers Operating Manual.doc 2018-08-21 [63][S][KL] – Programming AUX1 Timer, S=0..1, KL=00..99, default: S=0, KL=02 The AUX1 Timer defines triggering time for AUX1 Momentary output. When S=0 and KL=00 then output will be triggered indefinitely until the reader’s arming mode is switched. Program S=0 for seconds or S=1 for minutes.
Page 30
PRTxxEM series readers Operating Manual.doc 2018-08-21 Note: Setting S=0 and KL=00 will set unlimited open time thus will disable indication of a Door Ajar alarm. [73][S][KL] – Programming Duress Timer, S=0..1, KL=00..99, default: S=1 KL=03 This timer defines duration time for Duress Alarm. When S=0 and KL=00 then the alarm will be triggered indefinitely until the reader’s arming mode is switched..
PRTxxEM series readers Operating Manual.doc 2018-08-21 Programs PIN and card for Installer user. Optionally, program [82][PIN][#][#] to omit card programming or [82][Card] to omit PIN programming. [83][S][KL] – Programming “Pulse on Arming” timer, S=0..1, KL=01..99, default: S=0 KL=02 This timer defines duration time for pulse generated on [52] function output. Program S=0 for seconds or S=1 for minutes.
Page 32
PRTxxEM series readers Operating Manual.doc 2018-08-21 Buzzer Control Input, when shorted with supply minus activates buzzer. LED OPEN Control Input, when shorted with supply minus activates LED OPEN. Door Lock Output, whenever access is granted (no matter from primary or secondary or through exit button), this output is triggered for time specified by Door Unlock Time.
PRTxxEM series readers Operating Manual.doc 2018-08-21 Timer however whenever reader changes its arming mode this output is immediately cleared. When corresponding timer is set to 00s output it activated for unlimited time - till moment when reader changes its arming mode again. Intruder Alarm Output, line is triggered in the moment when Intruder Alarm is raised.
PRTxxEM series readers Operating Manual.doc 2018-08-21 9.1.1. User Programming Commands Note: Any attempt to program an already registered card or PIN will be indicated as a programming error. [11][PIN][#] – Add NORMAL user with PIN The new NORMAL user added with this function is stored in unoccupied (free) location of the memory i.e.
Page 35
PRTxxEM series readers Operating Manual.doc 2018-08-21 [20] – Delete all users Reader deletes all users (cards and PIN-s) so that all user IDs are released and can be programmed anew. The MASTER and INSTALLER users are not deleted with this function. [21][PIN][#] –...
PRTxxEM series readers Operating Manual.doc 2018-08-21 1 0 . R O G R A M M I N G R O M The reder can be fully programmed from the PC through standard COM port (RS232) or via dedicated RUD-1 interface (USB port). In both cases the RARC program is required. In order to establish the connection, select Options->Port command in RARC software, then Connection- >Connect…, the option RS232 and then the button Start.
Customers are kindly advised to register at the website so that Roger can send information as soon as new firmware versions is ready for download. Firmware can be uploaded to reader via ordinary RS232 COM port or RUD-1 (USB) interface. In both cases RogerISP 4 program is required.
PRTxxEM series readers Operating Manual.doc 2018-08-21 Note: Once the firmware upgrade is accomplished but programmed device doesn’t work then it may be necessary to start Memory Reset procedure and/or upload the firmware once more. 10.3.1. Firmware upgrade via RS232 COM port ...
PRTxxEM series readers Operating Manual.doc 2018-08-21 1 1 . N S T A L L A T I O N U I D E L I N E S Reader should be installed in such way as to ensure physical access to the connection cable, screw terminals and programming jumpers.
Page 40
PRTxxEM series readers Operating Manual.doc 2018-08-21 When lost or stolen a new MASTER and INSTALLER cards (PIN-s) can be reprogrammed in the reader. When the reader has been set for Terminal Mode (online unit connected to the host controller), programming of MASTER and INSTALLER users can be skipped.
Page 41
White of enclosure is open. Technical Specification Supply voltage Nominal 12VDC, min./max. range 10-15 VDC Current consumption PRT12EM: 65mA (average) PRT12EM-BK: 45mA PRT32EM: 65 mA PRT42EM: 65 mA PRT42EM-BK: 45mA PRT62EM: 45mA PRT64EM: 65mA...
Page 42
PRT62EM: Class IV PRT64EM/PRT64EM-VP: Class IV PRT66EM: Class IV Dimensions H x W x D PRT12EM/PRT12EM-BK: 150.5 X 46 X 23 mm PRT32EM: 105 X 105 X 31 PRT42EM/PRT42EM-BK: 151.5 X 45 X 20.5 mm PRT62EM: 100 X 45 X 25 mm...
Page 43
PRTxxEM series readers Operating Manual.doc 2018-08-21 PRT64EM Outdoor proximity reader with keypad, laser engraved long durability silicon rubber keypad, two function keys, dark grey ABS enclosure, screw terminals, pig- tail cable as option PRT64EM-VP Outdoor proximity reader with keypad, laser engraved long durability silicon rubber keypad, two function keys, silver metal enclosure including key-tops, pig- tail cable PRT66EM...
Page 44
PRTxxEM series readers Operating Manual.doc 2018-08-21 User list Reader name: Reader location: Card code Type User Name None MASTER None INSTALLER 44/54...
Page 45
PRTxxEM series readers Operating Manual.doc 2018-08-21 45/54...
Page 46
PRTxxEM series readers Operating Manual.doc 2018-08-21 46/54...
Page 47
PRTxxEM series readers Operating Manual.doc 2018-08-21 47/54...
Page 48
PRTxxEM series readers Operating Manual.doc 2018-08-21 48/54...
Page 49
PRTxxEM series readers Operating Manual.doc 2018-08-21 49/54...
Page 50
PRTxxEM series readers Operating Manual.doc 2018-08-21 50/54...
Page 51
PRTxxEM series readers Operating Manual.doc 2018-08-21 51/54...
Page 52
PRTxxEM series readers Operating Manual.doc 2018-08-21 52/54...
Page 53
PRTxxEM series readers Operating Manual.doc 2018-08-21 53/54...
Page 54
Weight of the equipment is specified in the document. Contact: Roger sp. z o.o. sp.k. 82-400 Sztum Gościszewo 59 Tel.: +48 55 272 0132 Fax: +48 55 272 0133 Tech.
Need help?
Do you have a question about the PRT12EM and is the answer not in the manual?
Questions and answers