Download Print this page

CyberData 011113 Installation Quick Reference page 2

Voip indoor intercom with keypad. sip compliant. ral 9003, signal white
Hide thumbs Also See for 011113:

Advertisement

Dimensions
6.5 [165]
DIMENSIONS ARE IN INCHES [MILLIMETER]
Terminal Block Connections
Wire in,
Wire in,
accept wire range
accepts 16 AWG gauge wire
up to 16 AWG
© 2011, CyberData Corporation, ALL RIGHTS RESERVED
930225G
1.6 [40]
Alternate Power Input:
1 = +12 to +24 VDC at 1000mA (500mA minimum)
2 = Power Ground
J3
Alternate Power Input:
Terminal Block
1 = +12 to +24 VDC at 500 mA
3
4
2 = Power Ground
Relay Contact:
(1A at 30 VDC for continuous loads)
3 = Normally Open Common
3
4 = Normally Open Contact
4
5 = Door Sense Input
Relay Contact:
6 = Door Sense Ground Reference
(2A at 30 VDC or 0.4A at 125 VAC
for continuous loads)
3 = Normally Open Common
4 = Normally Open Contact
5 = Door Sense Input
6 = Door Sense Ground Reference
Quick Reference
RTFM Switch
Wall Mounting Options
Backplate
Can Be Rotated
to Mount on Either Sides
Machine Screw
(4 Pieces)
Quick Reference
When the device is operational and linked to a
network, you can use the Reset Test Function
RTFM
Management (RTFM) switch (see picture) to
announce the device's IP address or restore the
device to the factory default settings.
To announce the device's current IP address:
• Press and release the RTFM switch within a
five second window.
Note
The device will use DHCP to obtain the
new IP address (DHCP-assigned
address or default to 10.10.10.10 if a
DHCP server is not present).
To restore the device to factory default settings:
• Press and hold the RTFM switch for longer
than five seconds.
Hole in Wall
(for Network Cable)
Pre-Drilled Hole
(4 Places)
Sheet Metal Screw &
Plastic Anchor (4 Pieces Each)
930225G
© 2011, CyberData Corporation, ALL RIGHTS RESERVED