LG LSE4617 series Owner's Manual page 18

Electric induction range
Hide thumbs Also See for LSE4617 series:
Table of Contents

Advertisement

Available languages

Available languages

18
INSTALLATION
3- W ire Connection: Conduit
I nstall th e conduit as follow s:
Remove the conduit connection plate from the rear of
the oven and rotate it. The conduit hole (1
be used.
First, prepare the conduit wires as shown below.
3- W ire
Conduit
connection
plate
Second, install the conduit strain relief.
For conduit installations, purchase a strain relief and
insert it in the 1
1
/
in. (2.8 cm) conduit hole. Then
8
install the conduit through the body of the strain relief
and fasten the strain relief with its ring. Reinstall the
bracket.
For conduit connections:
If the wire in the conduit is copper it must be 8 or 1 0
AWG
wiring.
If the wire in the conduit is aluminum it must be 6 or 8
AWG
wiring.
1
Loosen the lower 3 screws from the terminal
block.
2
Insert the bare wire (white/ neutral) end through
the center terminal block opening. D o not
remove the ground strap connections.
3
Insert the two side bare wire ends into the lower
left and the lower right terminal block openings.
Tighten the 3 screws securely into the terminal
block. (approx i mately 35 - 50 IN-LB)
3- w ire connection
Black White Red
Conduit
connection plate
If screws are not tightened securely, it can result in
electrical spark and severe personal inj ury or death.
1
/
" ) must
8
4- W ire
G round
wire
or
Terminal
block
Wire
ends
4- W ire Connection: Conduit
W A RN I N G
• T h e w h ite middle ( neutral) w ire of th e pow er
cord or 4- w ire conduit h as to be connected
to th e middle post of th e main terminal
block. T h e oth er tw o w ires of th e pow er
cord or conduit h av e to be connected to
th e outside posts of th e main terminal
connection block. T h e 4th ground w ire
( green) must be connected to th e frame of
th e range w ith th e ground screw . Failure
to do so can result in electrical shock, severe
personal inj ury or death.
1
Follow the instructions for installing the conduit
under 3-Wire Connection : Conduit until the strain
relief and bracket are installed. D o not install the
conduit without a strain relief.
2
Loosen the 2 lower left and right screws from
the terminal block. Remove the lower 2 center
screws. D o not discard any screws.
3
Remove the ground screw and bend the end of
the ground strap up so the slot is over the hole
of the center screw removed in step 1 .
4
Attach the ground (green) bare wire end to
the range frame and secure it in place with the
ground screw.
5
Insert the bare wire (white/ neutral) end through the
center terminal block opening. The center screw
now attaches the bent up ground strap to the block.
6
Insert the two side bare wire ends into the left
and the right terminal block openings. Tighten
the 3 screws securely into the terminal block.
(approx i mately 35 - 50 IN-LB)
4- w ire connection
Black White Red
Wire
ends
Conduit
connection
plate
G round
screw
If screws are not tightened securely, it can result in
electrical spark and severe personal inj ury or death.
Terminal
block
G round
strap
Bend strap
up and
attach
G round
wire

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lse4616 series

Table of Contents