Installing The Magnetic Clamping Fixture And Transducers - Mcf; Identifying The Mcf Components - GE CModel C-RS Installation Manual

Ultrasonic flow transducer
Table of Contents

Advertisement

6.4 Installing the Magnetic Clamping Fixture and Transducers - MCF

The Magnetic Clamping Fixture (MCF) is used to fasten transducers to the pipe at the proper spacing without chains or
straps. The MCF can be used only on ferrous pipe materials.
Different fixtures are used for the single- and double-traverse installations. Each type of MCF has magnets at both ends
of the fixtures. When the magnets are turned ON, the fixture magnetically "clamps" to the pipe wall.

6.5 Identifying the MCF Components

Refer to Figure 12 to identify the MCF components. Then proceed to the instructions for either the double-traverse
method or the single-traverse method.
Transducer Block
Magnetic Block
Pressure Bolt
Locking Nut
ON/OFF Switch
Optional
Thumbscrews
Safety Chain
Rails
Figure 12: Transducer Block and Magnetic Block - MCF