GE Baker Hughes Masoneilan 4411 Instruction Manual

GE Baker Hughes Masoneilan 4411 Instruction Manual

Electropneumatic transducer

Advertisement

Quick Links

Masoneilan*
4411 Model
Electropneumatic Transducer
ATEX Instruction Manual (Rev.D)
BHGE Data Classification : Public

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Baker Hughes Masoneilan 4411 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GE Baker Hughes Masoneilan 4411

  • Page 1 Masoneilan* 4411 Model Electropneumatic Transducer ATEX Instruction Manual (Rev.D) BHGE Data Classification : Public...
  • Page 2 © 2019 Baker Hughes, a GE company. All Rights Reserved. b | BHGE...
  • Page 3 SPECIFIC REFERENCE INFORMATION IN ADDITION TO THE CUSTOMER/OPERATOR’S NORMAL OPERATION AND MAINTENANCE PROCEDURES. SINCE OPERATION AND MAINTENANCE PHILOSOPHIES VARY, BHGE (BAKER HUGHES, A GE COMPANY AND ITS SUBSIDIARIES AND AFFILIATES) DOES NOT ATTEMPT TO DICTATE SPECIFIC PROCEDURES, BUT TO PROVIDE BASIC LIMITATIONS AND REQUIREMENTS CREATED BY THE TYPE OF EQUIPMENT PROVIDED.
  • Page 4: Table Of Contents

    Potentially Explosive Atmospheres — Markings ........................7 Instructions Specific to Hazardous Area Installations ......................8 Instructions — Special Condition for Safe Use ...........................8 FM Control Drawing ....................................9 CSA Control Drawing...................................10 © 2019 Baker Hughes, a GE company. All Rights Reserved. d | BHGE...
  • Page 5: Safety Warning

    • These instructions are written specifically for the 4411 IP Transducer, and do not apply for other instruments or IP transducers outside of this product line. © 2019 Baker Hughes, a GE company. All Rights Reserved. Masoneilan Model 4411 Electropneumatic Transducer Instruction Manual | 1...
  • Page 6: Brief User Guide

    WHEN USING JACK PLUG A SIGNAL DOES NOT HAVE TO BE SUPPLIED VIA THE TERMINAL BLOCK. THE INPUT SIGNAL CAN BE MONITORED THROUGH THE JACK PLUG SOCKET WHEN UNIT IS IN OPERATION. Figure 1 © 2019 Baker Hughes, a GE company. All Rights Reserved. 2 | BHGE...
  • Page 7: Instrument Mounting

    The ports are threaded 1/4" NPT at the back of the unit and 1/8" NPT at the front. © 2019 Baker Hughes, a GE company. All Rights Reserved. Masoneilan Model 4411 Electropneumatic Transducer Instruction Manual | 3...
  • Page 8: Electrical Installation

    The Jack Plug can be either set-up for Monitoring to explosion-proof specifications must be used. A ground or Calibration/Operation set-up. terminal is provided both internally and externally and should © 2019 Baker Hughes, a GE company. All Rights Reserved. 4 | BHGE...
  • Page 9: Tight Shut-Off Adjustment Instructions

    Erratic at all Controller cannot Reduce loop pressures provide 6.5V resistance continuously or change controller Contamination Check I/P filter status © 2019 Baker Hughes, a GE company. All Rights Reserved. Masoneilan Model 4411 Electropneumatic Transducer Instruction Manual | 5...
  • Page 10: Technical Specifications

    1/2" NPT (M20 option); 2 internal screw terminals for 2.5mm cable Weight: 2.07Kg Materials Aluminium and zinc diecasting with nitrile diaphragms, epoxy powder coat painting as standard. Weatherproof to Type 4X (IP66) [mounted upright]. © 2019 Baker Hughes, a GE company. All Rights Reserved. 6 | BHGE...
  • Page 11: Potentially Explosive Atmospheres - Markings

    For additional warnings that may apply for safe use and installation, refer to the Instructions – Special Conditions for Safe Use section of this manual as identified on ATEX certificates numbers with an ‘X’ suffix. © 2019 Baker Hughes, a GE company. All Rights Reserved. Masoneilan Model 4411 Electropneumatic Transducer Instruction Manual | 7...
  • Page 12: Instructions Specific To Hazardous Area Installations

    • Aggressive substances: e.g. acidic liquids or gases that may attack metals, or solvents that may affect polymeric materials. © 2019 Baker Hughes, a GE company. All Rights Reserved. 8 | BHGE...
  • Page 13: Fm Control Drawing

    © 2019 Baker Hughes, a GE company. All Rights Reserved. Masoneilan Model 4411 Electropneumatic Transducer Instruction Manual | 9...
  • Page 14: Csa Control Drawing

    © 2019 Baker Hughes, a GE company. All Rights Reserved.
  • Page 15 Notes: © 2019 Baker Hughes, a GE company. All Rights Reserved. Masoneilan Model 4411 Electropneumatic Transducer Instruction Manual | 11...
  • Page 16 The BHGE logo is a trademark of Baker Hughes, a GE company LLC. GE and the GE monogram are trademarks of the General Electric Company used under trademark license.

Table of Contents