5.3 The Double-Traverse Method -UCF (cont.)
4. Using the attached ruler, move the blocks so they are a distance S from each other. As shown below, use either the
pressure bolts or the ends of the blocks as reference points.
5. Position the clamping fixture along the horizontal plane of the pipe - not on the top or bottom. Make sure the
chains are both on the opposite side of the pipe from the slide track with the ruler.
C-RS Ultrasonic Flow Transducer Installation Guide
Centerline
S = Spacing
S = Spacing
S = Spacing
Centerline
Side View
9