Ultrasonic flow transducer
Table of Contents

Advertisement

5.4 The Single-Traverse Method - UCF (cont.)
7. From the second mark on the top of the pipe, measure in the opposite direction around the pipe for 1/4 of the
circumference. Make another crossmark at this point.
8. Center the long block over one of the crosssmarks on the pipe. Align the long block so that the pressure bolt is over
the center of the crossmark. Fasten the block by wrapping both chains around the pipe and fastening the chains to
the screw hooks on the opposite side of the block.
C-RS Ultrasonic Flow Transducer Installation Guide
Spacing
Crossmark
Fasten Chains
Side View
13