Mira Advance Installation, Operation, Maintenance Manual page 21

Electric showers. standard & memory models cove
Hide thumbs Also See for Advance:
Table of Contents

Advertisement

Section
8
Read the section "Important Safety Information"
If you are unsure how electric showers work, please read through, "Advice to users"
and "Mira Advance"
"Mira Advance" before continuing.
"Mira Advance"
"Mira Advance"
"Mira Advance"
1. 1. 1. 1. 1.
Connect the flexible hose from the shower fitting to the outlet of the Mira
Advance. Ensure that the hose seals are fitted, and that the handset is in the
handset holder and aimed into the water catchment area.
Do not
Do not
Do not
Do not overtighten. Over-tightening the flexible hose will shorten its life.
Do not
2. 2. 2. 2. 2.
Turn
Turn the 'TEMPERATURE'
Turn
'TEMPERATURE'
'TEMPERATURE' control knob to full
'TEMPERATURE'
Turn
Turn
'TEMPERATURE'
cold
cold
cold
cold
cold. The control knob operates through
approximately ¾ of a turn from cold to hot and
features a detent on the final travel to the cold
only position.
3. 3. 3. 3. 3.
Turn on
Turn on the water supply fully at the isolating
Turn on
Turn on
Turn on
valve. Check that water is not leaking from the
bottom of the case.
4. 4. 4. 4. 4.
Switch on
Switch on the electrical supply at the double-
Switch on
Switch on
Switch on
pole switch. The red indicator beside the 'STOP'
button will illuminate providing a visual indication
that the electrical supply is connected.
5. 5. 5. 5. 5.
Press
Press
Press
Press
Press the 'LOW'
green indicator and the audible tone. Check that
cold water flows freely from the shower within a
few seconds. If a delay of more than 5 seconds
in encountered, then it is likely that the Mira
Advance has not been primed. Refer to
" " " " " Installation
Installation". ". ". ". ".
Installation
Installation
Installation
Warning! Isolate the electrical supply as this step requires that the Mira
Warning!
Warning!
Warning!
Warning!
Advance cover be removed. Should the Mira Advance still not function then refer
to "Fault Diagnosis"
"Fault Diagnosis".
"Fault Diagnosis"
"Fault Diagnosis"
"Fault Diagnosis"
6. 6. 6. 6. 6.
Turn the 'TEMPERATURE'
'TEMPERATURE'
'TEMPERATURE' control knob to position '5' '5' '5' '5' '5' and allow the Mira
'TEMPERATURE'
'TEMPERATURE'
Advance to operate for 2 minutes. During this period the Mira Advance will
calibrate itself to the site conditions.
Commissioning
Commissioning
Commissioning
Commissioning
Commissioning
"Important Safety Information" first.
"Important Safety Information"
"Important Safety Information"
"Important Safety Information"
'LOW'
'LOW'
'LOW' flow button and observe the
'LOW'
full
full
full
full
'STOP'
'STOP'
'STOP'
'STOP'
"Advice to users"
"Advice to users"
"Advice to users"
"Advice to users"
Flow
21
21
21
21
21