A FUNCTlONAL DESCRIPTION, No. 4165 SIREN-DRIVER
(See Dlagmm 5)
Controte
PITCH ADJUSTMENT: The small potentiometer permits the
adjustment of the pitch of the sound produced by the siren driver.
Clockwise adjustment (as wewed from the right side of the cabinet)
Increases the pitch and the counterclockwise adjustment de-
creases the pitch.
. FUNCTIONAL DESCRIPTION, No. 6322 SECURITY CONSOLE
(See Dlagmm 6)
1. Keypad, LEDI and Mewge
Dlaplayr
Note While entries are being made via the keypad, II more than
two mconds elapse between successive key entrlea,
all prior entered information WIII be erased, thus requiring
the entry sequence to be started anew.
Keys O-9: These are used to enter the security code and the
duress code.
OFF Kev and LED IGreenl: When deoressed subseauent lo
entry of ihe security'code. s:lences ala&i. memory and trouble
audibles and disarms the system. The OFF LED is lit when the
system's burglary protection is turned off.
AWAY Key and LED (Red): When depressed subsequent to
entry of the secunty code, arms the entire burglary system if
there are no faulted zones. The AWAY LED is lit when the
system is armed in lhis mode.
STAY Key and LED (Red): When depressed subsequent to
entry of the security code, arms all of the burglary zones except
LDnes selected as interior protection if there are no faulted zones
(other than selected interior zones). The STAY LED is lit when
the system is armed in this mode.
POWER LED (Green): This LED indicates the presence of AC
power 10 operate the system. This LED will turn off immediately
when AC power is lost.
BYPASS KEY and LED (Ysllow): When depressed subsequent
lo entry of the security code (either before or after arming) and
followed by one or more zone numbers (1 to 6). will individually
bypass the zone(s) designated [assuming that the programming
of the system permits the bypassing of the particular zone(s)].
Following the entry of Ihe last zone lo be bypassed, all bypassed
zones will be displayed once at the console for 2 seconds. When
rhe bypassed zone appears, the console beeps. Any time the
security code is followed by depressing BYPASS key. the
bypassed zones will be displayed even if no new zones are
bypassed.
When depressed subsequent lo entry of the security code and
either the AWAY or STAY keys. the burglary system will arm
with any tautted zones bypassed [assuming lhat the programming
of the system permits bypassing of the particular zone(s)]. Arming
in this manner does not cause the numbers of the bypassed
zones to be displayed.
The BYPASS LED is lit when one or more zones is bypassed
either by force arming or by individual shunf selection. All
bypasses are automatically removed when the system is turned
on.
INSTANT Key and LED (Yellow): When depressed subse-
quent to entry of the security code and either the AWAY or
STAY keys, the burglary system will arm with the entry delay
disabled on any zones designated as entrylexil zones. making
them instant alarm zones for subsequent entry. The INSTANT
LED is lit when the system is in this mode. The entry delay for
these zones is restored subsequent to the system being turned
Off.
CODE Key: When depressed subsequent to entry of the master
security code, will permit the entry of a secondary code designa-
tor (2-6) followed by a user changeable 4 digit secondary securi-
ty code. Secondary codes 3-6 permit the performance of all of
the functions permitted by the PROM programmed master code
and secondary code 2 except change of themselves to a new code
or creation ot new secondary codes. Repeating digits are permil-
ted in code entries. If a secondary code entered happens 10 be
5
.
similar to the master
code
(or another secondary code) except for
the last digit being 1 higher. the duress silent panic capability will
be triggered, causing a needless false alarm to be reported IO the
central alarm monitoring servtce.
CHIME Key and LED (Yellow): When depressed subsequent
to entry of the security code during the disarmed state. will
cause entry to a mode where any fault in a zone PROM selected
for chime enable will cause a brief loud lone to be heard at each
security console and remote keypad. The mode can
be
turned
off by subsequent reentry of the
code and
redepression of the
CHIME key. The CHIME LED is lit whenever Ihe CHIME mode
is In effect. The CHIME mode is never in effect during the armed
state.
READY Key and LED (Green): When depressed a1 any time.
oermits the Zone Identification Disolav to identifv anv oresentlv
iaulted zones. Subsequent depresiion of code ; OFi iurns off'
the zone displays. The READY LED is lit whenever all zones are
intact (ready foi arming) during the disarmed
stale. It
is off at
other times.
ENTER Key: When depressed subsequent lo security code and
function or mode entry, eliminates the 2 second keying entry
delay that exists prior 10 acting on the function or mode request
(an optional entry).
FIRE and FIRE Keys: Simultaneous depression of both keys
causes manual activation of a PROM setectable zone. The
resultmg alarm will behave as if the zone was initiated externally
via a wired zone.
POLICE and POLICE Keys: Simultaneous depression of both
keys causes manual activation of a PROM selectable zone. The
resulting alarm will behave as if the zone was initiated externally
via a wired zone.
EYERG and EYERG Km
Simultaneous depression of bolh
keys causes manual activation of a PROM selectable zone. The
resulting alarm will behave as if the zone was initiated externally
na a wired zone.
For each of the three above palm 01 keys, It Is the lnstaller'r
responslblllty to program the keys for use with a zone Mng
the cb8meterlstla
de8lred.
LIGHTS l d LIGHTS Keys and LED (Red): Simultaneous
depression of both keys causes manual activation of the "Liles
On" output and the red LITES LED. The LITES LED also goes on
under program control. It remains lit until the system is disarmed.
ZONE IDENTlFlCATlON
DISPLAY (Red): This one digit dis-
play provides the zone identification for each zone programmed
as a burglary zone during the disarmed and armed states. for
both current tautts and memory of alarm.
ALARM LED (Red): This LED is lit subsequent lo activation of
one of the armed zones not defined as fire and remains, along
with the Zone I.D. Display, as a memory of alarm after the alarm
condition is removed.
TROUBLE LED (Red): This LED is lit subsequent lo a trouble
condiiion bemg detected in a zone setected for trouble annunci-
atiin and in the proper armed state as defined in Ihe controlled
options. The trouble indication will be removed only after all
troubled zones are
CDrreCted.
FIRE LED (Red): This LED is lit subsequent to activation of a
fire and remains, along with the Zone I.D. Display, as a memory
of alarm after the alarm condition is removed.
DIAL LED (Yellow): This LED lights steadily while any phone
transmission (except a silent alarm where me system is pro-
grammed for console inhibit) of an alarm. trouble. open/close,
cancel. or restore is in process. When the central alarm monitor-
ing service receiver acknowledges the transmission with a kiss-
off, the message will flash for 30 seconds.
NO DIAL LED (Red): This LED lights steadily until the system is
nexl armed if the maximum number of attempts lo get the mes-
sage through have been tried unsuccessfulty.