1. Fully oxplaln tha opemtlon of the syxtem to the uwr by going
through each of the features as well as the OWNERS MANUAL
supplied.
2. D&be
the owntlon
of l aoh zone. Clarify whfch contacts or
devices are used at nfght. which are used in the interior, whrch
are day/night (if programmed).
3. Encourage the wer to tlnd
and
remedy zone pmbtems arts-
lng when umtng the qstem. Show the user how to mdividually
bypass zones as well as how to force arm the system tn the pres-
ence of a bad zone.
A. No. 418~1214180EC CONTRDUCOMYUNICATOR
See
Diagrams 4 and 9.
1. Phylwl:
Wldthz
12%" (31.6 cm)
Helghtz
17-s" (43.8 cm)
Depth:
4-s" (11.1 cm)
2. Etoctrlwl:
Voltage:
18 VAC (from No. 1349 40 VA Plug-In Transformer)
Maximum Permlsstble Resistance (per zone): 600 Ohms (plus end-
of-line resistor: 1000 Ohms)
Zone Response:
250 msec (normal). 15 msec (fast)
Bell Reky (Wet) Output:
SPST. Maximum Output: 2A @ 12V.DC
12V.DC Regulated Output:
Continuous Power for Accessories. Smoke Detectors, Con-
soles and Keypads: 1 A max. for non-UL Listed applications
650 mA max. for UL Listed usage.
AnnlDtswm
Status Dutput
Armed: OV
Disarmed: +l ZV.DC. 10 mA
(reversible in PROM)
Fuses:
Five fuses -
No. 90-2: 2A. one for auxiliary current.
.No. 90-17: 4A. one for battery lead reversal protectron.
No. 90-12: 3A. one for optional siren driver (No. 4165)
and speaker power and for bell power.
_
No. 90-I 4: 1 A. one tor consoles/keypads and one for fire
detectors.
Standby:
12V Rechargeable Battery
(see chart below for battery types'available. and standby
times as a function of current drawn by all external loads)
YAXtMUM STANDBY TlMES WtTH VARIOUS AUXILIARY, SMOKE/
COMBtJSltON
DETECTOR. AND ADDtTlDNAL
CONSOLE/KEYPAD
CONltNUOUS
LOAD [ASSUMES THE USE OF (1) SECURITY CDN-
SOLE PLUS (1) REMOTE KEYPAD]
No. 45644
6V 5.4AH
WY
klx
.OAD
YA-NPBlT
MA)
12V 5AH
0
10.7
9.6
100
6.7
7.0
200
7.4
300
6.4
400
5.6
5.0
500
5.0
4.5
ZFI
4.3
4.6
4.1
3.9
700
4.0
3.7
600
3.8
3.5
900
3.5
32
000
3.3
3.0
BAlTERY TYPE
No. 46537
BV 27AH
WY
4.8
4.0
3.3
2.9
2.5
2.3
2.0
1.9
1.8
1.7
1.6
1.5
I
YAXlMUM STANDBY TtMES IN HOURS
l
Use of 12V 6AH battery is mandatory for UL Commercial installations
per UL Std. 609 (No. 4180-12 only); auxiliary load must not exceed
650mA to ensure standby time of at least 4 hours.
l
* Two batteries required, wired in series for 12 votts. Also. ORANGE
jumper on C-COM's PC board (behind insulating cover) must be cut.
See Diagram 9 for location.
NOTBt Banery normally need not be replaced for at least 3 years.
3. fnnsmtulon
Fomwt fE;zoeAad Ademco (and Silent Knight)
Radionrcs
Radionics "Superfast"
Ademco High Speed
Radionics "BFSK"
4. FCC Reglstmtlon No.: AC 398U - 68192 - AL - E
Ringer Equivalence O.OB
5. UL Lhttngr:
Nor. 410-12 and 41(10EC:
Household Fire/Burgtary (UL 985/1023)
No. 418&12 onty:
Ode
A Locrt
Merwntlle
Burglary (UL 609) (See Diagram 10).
Grade B CWItral Station Mercantlte Burgkry (UL 611) with No.
4179 Test Timer Module.
Orode A Central Statlon Mw&nttte
Bufgtmy (UL 611)
l
with No. 346 Reversing Relay Module. No. 4177 Relay Module and
No. 687 Voltage Regulator (see Diagram 12).
l
with No. 7620SE Long Range Radio Equipment. No. 4179 Test Timer
Module and No. 659EN tine Fault Monitor! (see Dfagram 13).
G~eM~n~alS~tknMerunHlsBurgluy(UL61
l)withNo.445
Lme Security Transmitter. No. 4177 Module and No. 667 Voltage Regu-
lator (see Diagram 11).
8. No. 4165 SIREN DRIVER (OPTIONAL)
See Diagram 5.
1. Phptcak
Wldthz
2-u" ( 6.6 cm)
Height
5-W (14.2 cm)
Dopthz
l"(2.5cm)
2.
Etedrlwk
See Diagram 6.
Voltege:
Operates trom 12V.DC
Lomd Capabltltyz 2A. max. at 12V.DC from C-COM. providing up to
25 watts into an 8 ohm speaker load. Speaker input
impedance must not be fess than 8 ohms.
IfltWl~:
Plug-in connection from front of C-COM P.C. board.
C. No. u22 SECURtTY CONSOLE
See Diagram 6.
1.
Phyalwl:
WtdL:
6-B" (17.7 cm) requires additional 3"
(7&m) clearance at right. if opening
01 iniormation drawer is desired.
Height:
4-%" (11.1 cm)
Depth:
l-2"
( 3.5 cm)
25

Advertisement

loading

This manual is also suitable for:

4180ec