Greenlee LPK1240 Instruction Manual page 22

12-ton hydraulic crimping tools
Hide thumbs Also See for LPK1240:
Table of Contents

Advertisement

An incomplete crimp can cause a fire.
• Use proper die, connector, and cable combina-
tions. Improper combinations can result in an
incomplete crimp.
• The relief valve sounds to indicate a completed
crimp. If you do not hear the sound of the relief
valve, the crimp is not complete.
Failure to observe these warnings could result in
severe injury or death.
Do not change accessories, inspect, adjust, or clean
tool or accessories when it is connected to a power
source. Accidental start-up can result in serious
injury.
Failure to observe this warning could result in severe
injury or death.
• Inspect tool before use. Replace any worn or
damaged parts. A damaged or improperly assem-
bled tool can break and strike nearby personnel.
• Inspect the hydraulic hoses and couplings every
operating day. Repair or replace if leakage, crack-
ing, wear, or damage is evident. Damaged hoses
or couplings can fail, resulting in injury or property
damage.
• Use this tool for manufacturer's intended use only.
Use other than that which is described in this
manual could result in injury or property damage.
Failure to observe these warnings could result in
severe injury or death.
Greenlee / A Textron Company
LPK1230 and LPK1240 12-ton Hydraulic Crimping Tools
IMPORTANT SAFETY INFORMATION
Do not exceed the following hydraulic power source
maximums:
• Hydraulic flow: 34.1 l/min (9 gpm)
• Pressure relief setting: 172 bar (2500 psi)
• Back pressure: 13.8 bar (200 psi)
Failure to observe this warning could result in severe
injury or death.
Do not disconnect tool, hoses, or fittings while the
power source is running or if the hydraulic fluid is hot.
Hot hydraulic fluid could cause serious burns.
Do not reverse hydraulic flow. Operation with
hydraulic flow reversed can cause tool malfunction.
Connect the pressure (supply) hose and tank (return)
hose to the proper ports.
Failure to observe this warning could result in severe
injury or death.
4