Chamberlain CSL24UL Installation Manual page 45

Elite series comercial dc vehicular slide gate operator
Table of Contents

Advertisement

Solar usage guide
System voltage
Main board with no radios programmed
®
One or more LiftMaster
remote controls programmed
®
MyQ
device or wireless dual gate programmed
Expansion board
Per loop detector LOOPDETLM (up to 3 loop detectors can be plugged in to the expansion board)
NOTE: The use of photoelectric sensor heaters (models LMRRUL and LMTBUL) is NOT recommended in solar applications.
BATTERY CURRENT
10W SOLAR PANEL
20W SOLAR PANEL
(Two 10W 12V panels
in series)
40W SOLAR PANEL
(Two 20W 12V panels
in series)
60W SOLAR PANEL
Typical System Standby Battery Current Consumption (mA)
Add up current draw by feature and accessory to determine total current draw
SOLAR GATE CYCLES PER DAY
DRAW (mA)
7AH batteries 33AH batteries 7AH batteries 33AH batteries 7AH batteries 33AH batteries
5
26
15
22
20
20
40
12
60
5
57
15
52
20
50
50
36
100
15
5
108
15
103
20
100
100
58
200
14
5
134
15
128
20
125
100
82
250
12
APPENDIX
ZONE 1
28
15
24
12
22
14
67
34
62
30
60
28
45
15
23
152
65
147
60
144
58
99
21
47
240
81
234
76
231
73
181
34
95
45
ZONE 2
17
13
11
40
14
36
10
33
20
92
27
87
23
84
21
44
146
34
140
29
137
27
92
20
24V
2.7 mA
+1 mA
+2.4 mA
+11.1 mA
+3.8 mA
ZONE 3
16
12
11
38
34
32
61
56
54
18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents