Parameter
Electrical data
Power supply
Fuse
Electric connections
Electric heater power
Cooling and water circuit
Refrigerant type
Refrigerant quantity
GWP
CO2 equivalent
Cooling circuit
Protection rating
Water connections - Enameled
Water connections – Stainless*
Water condensate connection
Nominal insulation thickness
Corrosion protection
Performance data
Outdoor air at 7°C (EN16147)
COP
Heat up time
Stand-by heat losses
Sound power
Indoor air at 20°C (EN16147)
COP
Heat up time
Stand-by heat losses
Sound power
Volume at 40°C
Auxiliary power
Unit
190L
V/Hz
A
-
W
-
g
1200
-
ton
-
-
in
mm
22 – Compression fittings
mm
mm
-
Magnesium anode / Stainless steel
-
hh:mm
06:28
W
dB(A)
-
4,13*
hh:mm
05:15*
W
dB(A)
L
W
230/50
13 (10)
L1, N, G
1500
R134a
1430
1,7
Hermetically sealed
IP21
¾ - BSPT (ISO 7-1)
Ø19
50
3.57
17
49
17*
55.6
247
1.61
*To be subjected to 3rd party test.
260L
1280
1,8
50
3.69
09:12
20
49
4.20
07:09
21
55.6
347
1.61
11