Genvex Combi 185 L User Manual

Genvex Combi 185 L User Manual

Heat pump and domestic hot water
Hide thumbs Also See for Combi 185 L:

Advertisement

GB

User Manual

Combi 185 L - LS - S
Optima 310
-Heat Pump and Domestic Hot Water
Version 3.04 - 0208

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Combi 185 L and is the answer not in the manual?

Questions and answers

Summary of Contents for Genvex Combi 185 L

  • Page 1: User Manual

    User Manual Combi 185 L - LS - S Optima 310 -Heat Pump and Domestic Hot Water Version 3.04 - 0208...
  • Page 2: Table Of Contents

    Optima 310 Table of contents Page Users Guide 1.1 Use ................3 Altering of the operation data ........3 1.3 Operating menu ............4 1.4 Week program ............9 1.5 Defrost program ............9 1.5 Special functions .............10 1.7 Factory default scheme ...........10 Function 2.1 Controller Optima 310..........11 2.2 Extra capacity ............11 2.3 Operation safety ............11 2.4 Warnings ..............11...
  • Page 3: Users Guide

    1: Optima 310 AC/EC T1: Supply air T2: Room All Genvex combined domestic ventilation- and water T3: Fresh air heat pumps and domestic hot water of the types Combi T4: Exhaust air 185, 185S, 185L and 185LS are supplied with optima...
  • Page 4: Operating Menu

    Optima 310 By pressing “OK”, the control system reverts to the main to use the electric heating element to supplement the menu and the text changes to English. Now all text in domestic water heating, as this leaves more heat from the the display appear in English.
  • Page 5 The set point may be set timer reaches the set value for filter change, the red between 0 - 5°C. Genvex logo will begin to flash on the control panel and the words “change filter” will appear on the display. The Operations menu >>Airflow 1 SUP...
  • Page 6 Optima 310 23: Airflow 3 SUP 31-36: Level 3 is the highest speed and is in use when having When the marker “>>” is pointing to menus between 18 and 23 the display heading changes to show actual many guests, when airing the rooms, having major activity in the kitchen, or if the unit is used for ventilating offices, changing point according to the following format: Changepoint, Weekday, Time.
  • Page 7 Optima 310 38: Default values 45: Water reg sec (Water heated supply air) Please notice: Before resetting the values please If a water after-heating coil has been installed in the ensure that the actual set points are noted in the supply air duct, it may be necessary to change the scheme page 43.
  • Page 8 Optima 310 Operations menu >> Danish 54 English 55 German 56 Polish Set point Exit < > 53: Danish Select language 54: English Select language 55: German Select language 56: Polish Select language...
  • Page 9: Week Program

    Optima 310 1.4 Week program scheme Tuesday Wednesday Monday Hours Minutes Red. T2 Hours Minutes Red. T2 Hours Minutes Red. T2 Friday Saturday Thursday Hours Minutes Red. T2 Hours Minutes Red. T2 Hours Minutes Red. T2 Sunday 1.5 Defrost program Hours Minutes Red.
  • Page 10: Special Functions

    Optima 310 1.6 Special functions 1.7 Factory default scheme Factory setting: Date: Date: Date: Summertime: Changing the clock between summer- and wintertime is done by simultaneously pressing “Enter” together with “Arrow Up” or “Arrow Down”. This will change the clock hour by 1 hour in the desired direction.
  • Page 11: Function

    (please se point 14 and 15). When the timer reaches the chosen value the display will read “change filter” and 3: No heating needs the red Genvex logo will flash until the filters has been When there is no need for either water heating or room changed.
  • Page 12: Connecting To Computer

    OPENING THE COVER. switch on the unit and press the enter button on the control panel for 10-15 seconds until the Genvex logo When the unit has been installed for the first time starts flashing again and the equipment is back in normal make sure the water drains are checked after a few days operation.
  • Page 13: Demounting

    To do this, press the spring-loaded arm on the safety valve and see if water comes out of the valve. Damage caused by a blocked safety valve is not covered by the Genvex warranty. Anode:...
  • Page 14: Fault Finding

    Optima 310 4. Fault finding The unit is equipped with the following safety equipment: 4.1 High pressure switch: For RESET press the white pin To prevent the compressor exceeding its range of application, there is an integral high pressure switch, which interrupts when the pressure becomes too high. In case of interruptions (too high pressure) the red light in the control panel will flash and the high pressure switch will stop the heat pump.
  • Page 15 Optima 310...
  • Page 16 Fax: +386/ (0) 2/460 13 55 E-Mail: pichler@pichler-co.si Switzerland SM-HEAG Klimatechnik AG CH-8307 Effretikon Tel.: +41 (0) 52 / 355 11 00 Fax: +41 (0) 52 / 355 11 05 Published by Genvex A/S, Sverigesvej 6, DK-6100 Haderslev E-Mail: info@sm-heag.ch www.genvex.dk...

This manual is also suitable for:

Combi 185 lsOptima 310Combi 185