Dme Channel Sources; Table 1-1 Shifted Bcd Dme Channeling Codes - Honeywell BendixKing KN 62A Installation Manual

Distance measuring equipment
Table of Contents

Advertisement

BENDIX/KING
POWER REQUIREMENTS:
066-1068-04 AND 066-1088-01 ONLY
BACKLIGHTING:
CHANNELING SOURCES:
1.3.1

DME CHANNEL SOURCES

The KN 62/62A/64 can be channeled by the internal channeling tunning knobs or it may be chan-
neled by an external source. The KN 62/62A/64 will accept external channeling in the form of
Shifted BCD, ARINC 2X5, or Bendix/King Slip code. The tunning logic for each of the three types
of channeling is given in tables 1-1, 1-2, and 1-3.

TABLE 1-1 SHIFTED BCD DME CHANNELING CODES

Frequency
M8
Mhz
108
0
109
0
110
0
111
0
112
0
113
0
114
0
115
0
116
1
117
1
0 = Connected to Remote Control Common
1 = Open
Rev 7, November/2004
M4
M2
M1
.X
Mhz
0
0
0
.0X
0
0
1
.1X
0
1
0
.2X
0
1
1
.3X
1
0
0
.4X
1
0
1
.5X
1
1
0
.6X
1
1
1
.7X
0
0
0
.8X
0
0
1
.9X
00144I06.TDC
11-33VDC at 15 watts
NOMINAL 14VDC AT 2 WATTS
NOMINAL 28VDC AT 2 WATTS
a. Internal
b. External control head providing shifted
BCD code such as KFS 560B.
c. External control head providing ARINC 2 x
5 code such as KX 170 and KFS 560B.
d. External control head providing slip code
such as KX 170A, KX 170B, KX 175A, and KX
175B.
K80
K40
K20
0
0
0
0
0
0
0
0
0
0
0
1
0
0
1
0
1
0
0
1
0
0
1
1
0
1
1
1
0
0
1
0
0
KN 62/62A/64
K10
.XX
K50
0
Mhz
0
.X0
1
1
.X5
0
0
1
0
1
0
1
0
1
Page 1-3