Dip Switch Functions

Supported
SW
Channel
SW01
1
Channel 1
2
Channel 2
3
Channel 3
4
Channel 4
5
Unused
6
Unused
7
Unused
8
Unused
SW02
1
Channel 1
2
3
Channel 2
4
5
Channel 3
6
7
Channel 4
8
SW03
1
Unused
2
Unused
3
Unused
4
Unused
5
Unused
6
Unused
7
Unused
8
Unused
SW06
M-NET address
SW07
SW08
Communication error status display (error code
1
display)
Temporary mask setting
2
Unused
3
Unused
4
Unused
5
Unused
6
Unused
SW09
1
Unused
2
Unused
Set the dip switches for function selection according to the system to be used.
At factory default, all dip switches are set to OFF and the M-NET address is set to 01.
Be sure to turn off the power before changing switch settings.
*1: If a system controller (G(B)-50A or TG-2000A) is connected, select the "SC setting" (factory default) and set the pulse unit (weight) value settings
from a system controller. If set to another setting, this dip switch setting is prioritized even when set from a system controller.
*2: The pulse unit of the watt-hour meter being used should be 1 kWh/pulse or less. Note that the apportioning error will increase if a watt-hour meter
with large pulse unit is used.
Function
Use of input contact
Use of input contact
Use of input contact
Use of input contact
Pulse unit (weight) value setting:
SC setting (*1):
× 0.1:
× 1:
× 10:
Pulse unit (weight) value setting:
SC setting (*1):
× 0.1:
× 1:
× 10:
Pulse unit (weight) value setting:
SC setting (*1):
× 0.1:
× 1:
× 10:
Pulse unit (weight) value setting:
SC setting (*1):
× 0.1:
× 1:
× 10:
OFF
ON
No
Yes
No
Yes
No
Yes
No
Yes
SW02-1
SW02-2
OFF
OFF
OFF
ON
ON
OFF
ON
ON
SW02-3
SW02-4
OFF
OFF
OFF
ON
ON
OFF
ON
ON
SW02-5
SW02-6
OFF
OFF
OFF
ON
ON
OFF
ON
ON
SW02-7
SW02-8
OFF
OFF
OFF
ON
ON
OFF
ON
ON
(Address 10s) 0 to 9
(decimal)
(Address 1s) 0 to 9
(decimal)
Change the switch to ON
once and then return it to
OFF.
11
Remark
Set whether to use the Channel 1 input.
Set whether to use the Channel 2 input.
Set whether to use the Channel 3 input.
Set whether to use the Channel 4 input.
Set to OFF
Set to OFF
Set to OFF
Set to OFF
Set 1 pulse of the meter connected to channel 1.
3
Unit: [kWh/pulse] [m
/pulse] [MJ/pulse]
Set 1 pulse of the meter connected to channel 2.
3
Unit: [kWh/pulse] [m
/pulse] [MJ/pulse]
Set 1 pulse of the meter connected to channel 3.
3
Unit: [kWh/pulse] [m
/pulse] [MJ/pulse]
Set 1 pulse of the meter connected to channel 4.
3
Unit: [kWh/pulse] [m
/pulse] [MJ/pulse]
Set to OFF
Set to OFF
Set to OFF
Set to OFF
Set to OFF
Set to OFF
Set to OFF
Set to OFF
An address from 01 to 50 can be set.
Set an address that is not the same as that of
another unit.
Only enabled during communication error status
display.
* The communication error status display is
masked for 10 seconds and the contact input
status is displayed.
Set to OFF
Set to OFF
Set to OFF
Set to OFF
Set to OFF
Set to OFF
Set to OFF