Wiring Diagrams - Gira 180 plus Installation Instructions Manual

Observer (pir)
Table of Contents

Advertisement

GIRA
Observer 180 plus
Info
Installation Instructions
ZEIT
LUX
Time
SENS.
1 min
5 min
3 sec
15 min
Test
Notes:
After the observer has switched off, a delay time of 3 seconds must be waited before switching on
takes place again.
Turning on the mains supply triggers a switching process of the observer. If this is not desired, please
install an additional switch, as shown in the connection diagram.
When the lighting is off, unfavourable installation conditions may cause reclosing by detection of the
lamps (cooling down and hence different heat rate), due to reflection of heat radiation from the lighting,
or due to too close a spacing between the observer and the lighting fixture. In this case, reduce the
sensitivity.
L
N
S
L
N
T
BK
BN
BU
Observer 180 plus
If no push-button for the additional functions has been installed for
the 180° observer, the test mode can also be set on the unit.
Select the following for the function test:
Time setting:
Brightness setting:
Sensitivity:
After the function test, you can set the time and brightness value
as desired.

Wiring Diagrams

Existing Installation
Connecting the Observer
Replace existing switch 'S' by additional functions push-button 'T'
(normally closed contact).
For each operation, the push-button must be held pressed for
at least 200 ms, while the next operation must be done within
2 seconds. After this, the additional function selected will be
activated.
BK (black):
L
BU (blue):
N
BN (brown):
28/99
Approx. 3 sec.
Day-time operation.
Individual, please refer to the illustration.
Page: 8 of 13