JUKI MS-1261A-DWS Instruction Manual page 51

Table of Contents

Advertisement

No
Item
U068
Presser-foot operation
changeover
U069
First-level presser-foot
lifting height
U070
Second-level press-
er-foot lifting height
U073
Re-try function
U087
Pedal acceleration char-
acteristic
U090
Upper stop function at
the initial operation
U096
Maximum sewing speed
U120
Main-shaft reference
angle correction
U121
Upper-position starting
angle correction
U122
Lower-position starting
angle correction
U182
Sewing count stop func-
tion
U183
Number of times of
thread trimming for the
sewing counter
U201
Cloth puller lifting height
U205
Selection of the up-
per-position returning
operation by a depress
on the back part of pedal
U206
Function for lifting the
cloth puller by a depress
on the back part of pedal
Setting range
0 to 1
This memory switch data item is used for setting the press-
er-foot lifting operation when the back part of pedal is de-
pressed.
0:2-step operation
1: Manual operation according to the stroke determined by
depressing depth of the back part of pedal
0.1 to 10.0 mm
This memory switch data item is used for setting the lifting
height of the presser foot when the back part of the pedal is
depressed to the first level.
0.1 to 10.0 mm
This memory switch data item is used for setting the lifting
height of the presser foot when the back part of the pedal is
depressed to the second level.
0 to 1
0: No re-try 1: Normal re-try
–10 to 10
-10 - -1: Low-range low acceleration
0: Standard
1 - 10:Low-range high acceleration
0 to 1
0: The sewing machine stops with its needle up after checking
the setting on the operation panel
1:The sewing machine stops with its needle up automatically
150 to 5500 sti/min
–30 to 30 degrees
This memory switch data item is used for setting the set value
for correcting the angle (0 degree) of the main shaft reference
signal.
–15 to 15 degrees
This memory switch data item is used for setting the set value
for correcting the main shaft angle at which the sewing ma-
chine stops with its needle up.
–15 to 15 degrees
This memory switch data item is used for setting the set value
for correcting the main shaft angle at which the sewing ma-
chine stops with its needle down.
0 to1
0: The sewing machine does not stop according to the sewing
count
1: Start of sewing machine is prohibited after performing
thread trimming when the counter has reached the set
value.
1 to 99
In the case of "U14 = 1", this memory switch data item is
used for setting the number of times of thread trimming (the
number of times that the back part of pedal is depressed to
the 2nd level) when using the sewing counter In the case of
"U14 = 3", this memory switch data item is used for setting
the number of times of sewing of materials to be performed
until the sewing counter value increases one.
0.1 to 10.0 mm
This memory switch data item is used for setting the height of
the cloth puller to be reached when lifting the cloth puller by
depressing the back part of pedal.
0 to 1
0:Normal returning to the upper position
1: Returning to the upper dead point by reverse rotation
0 to 2
This memory switch data item is used for setting the depress-
ing position of the back-part of pedal to lift the cloth puller.
0: Simultaneously with the presser foot (by depressing the
back part of peal to its 1st level)
1: After the presser foot (by depressing the back part of pedal
to its 2nd level)
2: The cloth puller is not lifted
– 48 –