Electrical Monitoring (Microprocessor Control); Pressure Relief Valve - Lincoln SSV-E User Manual

Quicklub - progressive metering devices for grease and oil
Table of Contents

Advertisement

User Manual
Operating Instructions
Monitoring of the Operation, continuation
Fig. 24
Piston detector installed on the metering device
Fig. 25

Pressure relief valve

SKF Lubrication Systems Germany GmbH ● Heinrich Hertz-Str. 2-8 D-69190 Walldorf Tel. +49(0) 6227 33-0 ● Fax: +49 (0) 6227 33-259
Mode of Operation, continuation
00002634
4092a97

Electrical monitoring (microprocessor control)

A piston detector (initiator), which has been installed on
a metering device instead of a piston closure plug
(M 11 x 1), monitors the pump operating time and brings
it to a close after all the pistons of this metering device
have dispensed their lubricant quantity.
If there is a blockage in the system or if the pump reser-
voir is empty, the piston detector can no longer record the
piston movements. The switching off signal is not trans-
mitted to the control unit. A fault signal occurs.
NOTE
For the system monitoring it is recom-
mended that one SSV-N metering device
with pre-assembled piston detector be
used per lubrication circuit. These special
6001a02
metering devices must be ordered sepa-
rately for each lubrication system. Refer to
the Parts Catalogue.
The pre-assembled metering devices have the designa-
tion SSV ... - N (they are available for SSV 6, 8, 10
and 12). They must be installed in the system instead of a
normal metering device.
Applications:
Metering device
piston detector
SSV
6001a02
SSV
SSV
Pressure relief valve
The whole system can be monitored visually via the pres-
sure relief valve. If lubricant is leaking at the pressure re-
lief valve during the distribution sequence, this indicates
that there is a blockage in the system.
IMPORTANT
In the case of the progressive metering
devices models SSV6 to 22 and SSV6-E
to 22-E outlets 1 and/or 2 must never be
closed, otherwise the system will block
6001a02
owing to the structure of the metering
device.
NOTE
Pressure relief valves to be ordered sepa-
rately (see parts catalogue).
2.2EN-20001-J11
-
Control unit / pump
M08-23 / P203
-NE
MF01,02 / P223
MDF01,02,03 / P233
PLC external
-N
-NP
control unit
P
15 f 24

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ssv mSsv

Table of Contents