Technical Data - CAMDEN CM-120wV2 Installation Instructions Manual

Ver. 3 digital keypads
Table of Contents

Advertisement

when any incorrect code has been entered, for the
duration that the red LED is illuminated.
0 = disabled
1 = enabled
To disable the audio tone on incorrect code entry:
First, enter program mode. Then enter [*6], then 3#,
then 0 to disable, or 1 to enable, then *.
For example, [*6] 3 # 0 * will disable the audio tone
on incorrect code entry.
5# Request to Exit Audio Enable/
Disable
Default: 0 (Disabled)
Enable or disable audio annunciation for Relay #1
when a Request to Exit signal is input. When
enabled, if Relay 1 is triggered by REX input, a
looped tone (do-ray) will be annunciated for the
duration that Relay #1 is energized. In the case of
Toggled mode, the annunciation will last for 8
seconds (hard-coded). In the case of entering into
Unlocked Mode (REX input held for more than 15
seconds), 4 beeps will sound after the looped two-
tone annunciation. A single ("Ray-Do") tone will
sound when exiting Unlock Mode.
0 = disabled
1 = enabled
To enable/disable REX Audio Annunciation:
First, enter program mode. Then enter [*6], then 5#,
then 0 to disable, or 1 to enable, then *.
For example, [*6] 5 # 1 * will enable the audio
annunciation for REX input.
6# Secure LED Annunciator
Enable/Disable
Enable or disable the Red LED annunciating the
secured status of the locked device. When enabled,
the red LED will light when the keypad is secured.
Once a valid code is entered into the keypad, the red
LED will turn off and the green LED will illuminate to
indicate the locked device is unlocked. The green
LED will remain lit for the duration set by the Relay
1/Relay2 on-time duration setting or until the locked
device closes (requires a magnetic door contact).
0 = disabled (default)
1 = enabled
To use this feature:
First enter program mode. Then enter [*6], 6#, 0 to
disable or 1 to enable, then *.
For example, [*6] 6 # 1 * will enable the red LED to
annunciate the status of the locked device.
FACTORY DEFAULT SETTINGS
If the settings have not been changed after shipment,
or if they have been reset, they are as follows:
o Master User # 1 - Code is 1234.
o Main Relay = 8 sec
o Secondary Relay = programmable.
o Yellow LED enabled.
Reset Jumper
To reset the Master User Code to factory default:
There is a three pin header located on the back of the
keypad. Move the jumper from pins
for at least three seconds, then back to pins 2 & 3
again.
During the reset, the LED's will blink four times, and
an audio tone will sound. This will reset the Master
code ONLY back to factory default (1234). While the
default jumper is located on pins
in the "LOCKED" state (no user input is accepted), so
be sure to move the jumper back to pins
[*9] Erase Keypad Memory/Reset ALL to
Factory
Force factory default settings (use with caution)
This is used when most or all of the programming has
to be changed, as when a keypad has been moved to
a new location. To reset to factory defaults.
First, enter program mode. Then enter [*9], then re-
enter the master keycode, then *.
For example, [*9] 1 2 3 4 * will immediately and
permanently clear the entire memory (assuming the
master keycode has not been changed from the
factory default. Once this function has been executed,
there is NO WAY to restore the previous
Section 4 _________________

Technical Data

Models
Illumination
Size
Mounting
Temperature
Operating voltage
7
Installation Instructions
to pins
2 & 3
, the keypad is
1 & 2
.
2 & 3
state.
CM-120i / CM-120W
No
/ Yes
2 ¾" x 4 ½" x ¾"
69.85mm x 114.30mm x
19.05mm
2 x #6-32 machine screws
-40° - +185°F (-40° - +85°C)
12 / 24 Volts, AC / DC
1 & 2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cm-120i

Table of Contents