CAMDEN CM-120wV2 Installation Instructions Manual page 5

Ver. 3 digital keypads
Table of Contents

Advertisement

[*0] Set "Latching Mode" for a User
Default: 0 (Disabled)
When enabled, the specified user keycode becomes
a "latching" code. Entering a "latching code will toggle
the state of relay 1.
0 = Disabled
1 = Enabled
NOTE: When the keypad is operating with "force
unique user codes" disabled (the default), users may
have identical codes. If individual control of "latching
mode" is required, consider enabling the "force
unique user codes" option.
To set a users access to "latching mode":
First, enter program mode. Then enter [*0], then the
user number, then '#', then (0 to disable latching
mode or 1 to enable it), then *.
For example, [*0] 1 2 # 1 * will set user number 12 to
"latching mode" access.
NOTE: If the the Relay Output mode has been set to
Split, then this latch mode affects only the relay
associated with that user number (memory location)
If the Relay Output Mode has been set to Sequence,
then the user Latching mode affects both relays. (So
both relays toggle on & off simultaneously).
[*4] Alarm Control Functions
0# Incorrect code alarm
Default: 0 (Disabled)
Use to control how the "Incorrect code alarm" is
annunciated.
0 = disabled
1 = buzzer
2 = relay 2
3 = both buzzer and relay 2
If the "Incorrect code alarm" is enabled, and triggered,
a valid code is required to reset.
To program how the "incorrect code alarm" condition
is annunciated:
First, enter program mode. Then enter [*4], then 0#,
then the annunciation code, then *.
For example, [*4] 0 # 1 * will configure the keypad
indicate entry of the programmed count of invalid
codes on the buzzer only.
2# Stuck key alarm
Default: 0 (Disabled)
Enable or disable the "Stuck key alarm".
0 = disabled
1 = enable
The "Stuck key" alarm will activate the buzzer after 15
seconds (factory set delay) of the key being held
continuously, and reset as soon as the key is
released (or after 10 seconds, whichever occurs first)
To enable the "stuck key alarm":
First, enter program mode. Then enter [*4], then 2#,
then (0 or 1), then *.
For example, [*4] 2 # 1 * will configure the keypad to
activate the stuck key buzzer.
3# Door Prop open Alarm
Default: 0 (Disabled)
Use to control how the "Door prop open alarm" is
annunciated.
0 = disabled
1 = buzzer
2 = relay 2
3 = both buzzer and relay 2
To program how the "Door Prop open alarm"
condition is annunciated:
First, enter program mode. Then enter [*4], then 3#,
then the annunciation code, then *.
For example, [*4] 3 # 3 * will annunciate by both the
buzzer and by activating relay 2.
NOTE 1: The alarm will sound continuously until
reset. To reset, enter valid code.
NOTE 2: To set Delay Time, see [*3] 2# on Page 4.
5# Incorrect code alarm lockout
Default: 0 (Disabled)
Use to configure the incorrect code alarm lockout.
0 = disabled
1 = enabled
To program:
First, enter program mode. Then enter [*4], then 5#,
then the enable/disable code, then *.
For example, [*4] 5 # 1 * will configure the keypad to
lockout for 2 minutes (factory set lockout duration),
after the incorrect code count alarm limit is reached.
During the lockout period, all keypad entry (including
correct codes) is ignored.
There is an automatic reset after 2 minutes.
(See 2# on Page 3 of manual for setting code count)
6# Door Forced open Alarm
Default: 0 (Disabled)
Use to control how the "Door forced open alarm" is
annunciated.
0 = disabled
1 = buzzer
5
Installation Instructions