CAMDEN CM-120wV2 Installation Instructions Manual page 3

Ver. 3 digital keypads
Table of Contents

Advertisement

2# Incorrect Code Count Alarm
Default: 0 (disabled)
When set to zero, the keypad will not alarm on entry
of invalid codes. When set to a value between 1 and
20, the keypad will generate an alarm after the
specified number of invalid codes have been entered,
within two minutes.
For example, [*1] 2 # 6 * will set the keypad to
generate an alarm when 6 invalid user codes have
been entered.
NOTE: This setting also requires the "Incorrect code
alarm Lockout" feature enabled. See 5# on page 5.
3# Force Unique User Codes
Default: 1 (Enabled)
When set to zero, the keypad will accept any user
code for each user. When set to one, during
programming of new user codes, the keypad will
check
the
desired
code
programmed users, and only accept the user code if it
is unique. Attempting to program a code that is not
unique
will
cause
an
programming procedure must be restarted and a
different code selected.
NOTE: when enabling this mode (when previously
disabled), it is recommended the administrator erase
all settings back to factory defaults first, to ensure all
user codes are unique. Failure to perform this step
may leave duplicate user codes among those already
learned, and result in unexpected operation.
0 = disabled
1 = enabled
For example, [*1] 3 # 0 * will disable "Force Unique
User Codes".
4# Anti-tailgating Enable / Disable
Default: 1 (Enabled)
Enable or disable the Anti-Tailgating feature. When
enabled, the keypad will release relay 1 immediately
after sensing the door has opened (via the door
contacts).
This
ensures
immediately when the door closes, reducing the risk
of tail-gate entry.
0 = disabled
1 = enabled
To disable the anti-tailgating feature:
First, enter program mode. Then enter [*1], then 4 #,
then 0 to disable, or 1 to enable, then *.
For example, [*1] 4 # 0* will disable the anti-tailgating
feature.
against
all
currently
error
alarm,
and
the
the
lock
re-engages
5# Backlight Control Enable/ Disable
(applies to CM-120W only)
Default: 0 (disabled)
Enable or disable backlight control on keypress.
When enabled, the backlight will be OFF until the first
keypress. It will remain on for 5 seconds after the last
keypress. When disabled, the backlight will remain
ON continuously.
0 = disabled
1 = enabled
To enable/disable Backlight Control mode:
First, enter program mode. Then enter [*1], then 5#,
then 0 to disable, or 1 to enable, then *.
For example, [*1] 5 # 1 * will make backlight turn
off until the first keypress.
6# User Two "Global Lockout"
Default: 1 (Enabled)
When enabled, user #2 (a manager, for instance) can
lockout all other users by prefixing his code by two (or
more) "#" keys. When a global lockout is engaged, no
user code will activate the outputs, except user #1 &
#2. Programming functions, and request to exit (REX)
are not disabled. This can be used (for instance) to
immediately control all access while changing
selected user codes in case of a security problem, or
for lockout over a weekend.
To disable user two "global lockout" feature:
First, enter program mode. Then enter [*1], then 6#,
then 0 to disable, or 1 to enable, then *.
0 = disabled
1 = enabled
For example [*1] 6 # 0 * will disable user #2's ability
to engage a global lockout.
Note: When user number #2's key code is prefixed
with two or more '#'s, the "Global User Enable/
Disable" flag will be toggled.
7# Relay Output Mode
Default: 0 (Relay 1 Only)
This control allows the installer to select the relay
output mode. Chosing the default (0) means that a
valid code activates Relay 1 only, and Relay 2 is
available for the various alarm conditions.
Setting the Relay Output Mode to "1" will allocate the
first 499 user numbers (memory addresses) to Relay
1, and the remaining 500 user numbers to Relay 2.
Setting the Relay Output Mode to "2" will sequence
Relay 1 & 2 with an adjustable delay between the two
outputs. Each relay will also have its own adjustable
delay-on-release time.
3
Installation Instructions

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cm-120i

Table of Contents