Current Draw
30 mA standby, 90 mA max.
Capacity
999 User codes
Length
Up to 8 digits (10 million
possible codes)
Response time
0.3 seconds
Inputs
1 x REX input
1 x Door Contact input
Relay Output
2 x Form C (SPDT)
Relay contact rating
3 amps @ 24 VDC/120 VAC
Wiegand Output
26 bit raw (opt. Facility code)
RF Output
2-channel w/ optional TX-99
Time Delay
1 to 255 seconds, or Latched
Section 5_________________

Warranty

Camden Door Controls guarantees the CM-120i or
CM120W to be free from manufacturing defects for 3
years from date of sale. If during the first 3 years the
CM120i or CM120W fails to perform correctly, it may
be returned to our factory where it will be repaired or
replaced (at our discretion) without charge. Except as
stated herein, Camden extends no warranties
expressed or implied regarding function, performance
or service.

Troubleshooting Tips

o If you make an input error (e.g. if you enter a
non-existent User Code) and press the star key, the
red LED will light. Simply start over.
o If you make an input error and have not yet
entered *, just wait 5 seconds, and the command
memory will be cleared automatically. Start again.
You will not increment the error count.
o The "Lockout-on-#-errors" feature is disabled by
default. This will prevent the keypad from hanging up
if
anyone
plays
with
applications.
the
keypad
in
certain
5502 Timberlea Blvd.,
Mississauga, ON Canada L4W 2T7
o Do not make the mistake of thinking you have to
'clear' the red light if you make an error. Just re-enter
the correct number. The red LED will clear
automatically with the first key you press.
o Be sure you are pressing the buttons firmly. The
yellow LED should come on and an audio tone
should sound with each key pressed, unless these
features have been disabled.
○ When using the optional TX-99 plug-in transmitter,
follow the 'learn-in' procedure documented in the
RX-91 or RX-92 Receiver installation manual. The
Keypad counts as one device to the receiver
regardless of how many pin codes learned into the
keypad.
Visit us online at
Call us toll-free at 1-877-CAMDEN9 or
(905)366-3377
www.camdencontrols.com
Toll Free: 1.877.226.3369
8
Installation Instructions
Questions?
www.camdencontrols.com
File: CM-120_NF_MAN Rev4
Firmware Version: 1.1
Revised: July 24, 2018
40-82B144
Part No.:

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cm-120i

Table of Contents