WARNINGS
All warnings are self-eliminating, except Error code 05.
It is possible to cancel a warning, but when the error remains, the warning will return after 60 seconds. This
gives the operator time to solve the problem without having the alarm on.
Error 00
"Low hopper level"
If this warning appears, the material in the hopper is below the hopper empty weight
(700 gr.)
In CONFIGURATION menu this setting can be changed.
- Check to see if there's enough material in the hopper.
- Check the hopper empty setting in CONFIGURATION menu
- Check to see if the hopper loader is working properly.
Error 01
"Maximum deviation exceeded"
If this warning appears, the feeding output (grams/sec) is consistently not within set
percentage. See page ? for more information.
Error 02
"Filling system unable to load material"
If this warning appears, the alarm time (ME hopper loader) or alarm cycles (MV hopper
loader) are exceeded.
- Check to ensure there is enough material in the hopper.
- Check if the material is clogged.
- Check the operation of the hopper loader.
- Check the hopper loader settings.
Error 03
"Maximum RPM exceeded, change feeding tool for higher capacity"
Calculated motor speed is higher than the maximum of 200 RPM
- Check the material output on 200 RPM.
- Check the production settings.
- Increase the feeding time (if possible)
- Take another dispensing cylinder with higher output, for example a feed screw A20
Error 05
"Calibration, no weight change"
No weight change while calibrating (see Section 7.6)
- Check to ensure there is enough material in the hopper.
- Check if material is stuck in the feeding cylinder.
- Check to ensure the loadcell is connected correctly.
- Check the weight data by doing a weight check (See Section 7.5)
- Check to see if there are vibrations that may have influence.
- Check the rotation direction of the dispensing cylinder. Front view to the right
Error 07
"Minimum motor speed < 0.1 RPM"
Calculated motor speed is lower than the minimum of 0.5 RPM
- Check to see if there's enough material in the hopper.
- Check the production settings.
- Decrease the feeding time (if possible)
- Use a different dispensing cylinder type with lower output, for example a GL-cylinder
- Check the rotation direction of the dispensing cylinder. Front view to the right