7.3 Keyboard lock

The keyboard lock function:
Is accessible in the LOGIN menu.
Can only be activated and deactivated with the SUPERVISOR login code.
Is only fully functional in OPERATOR and TOOLING user levels.
For example: if the "Start user" setting is configured to "Supervisor", the keyboard lock is deactivated as
soon as the controller is switched OFF and ON.
The following screen will appear when the LOGIN menu is entered:
USER
LEVEL
Enter the password to set
the user level.
Level
: SUPERVISOR
Key lock: Unlocked/Locked
MESSAGE
Keyboard locked !
To unlock enter
supervisor code.
MENU to continue
When "Locked" is selected it is still possible to:
Shift between the LOGIN, PRODUCTION and HOPPER LOADER menu.
To START and STOP the feeder.
For further information see the Start-up & Login Section 7.2.
Use the " " or " " arrow buttons to select "Locked" or "Unlocked" for the
keyboard, then press "Enter" to confirm. When "Locked" is selected the unit will
automatically be set to OPERATOR level.
This screen will appear when a user is trying to change settings while the keyboard
is locked. To unlock the keyboard, the supervisor code must entered in the LOGIN
menu.
14