7.10 Alarms

GENERAL
To reset an alarm/warning press the "STOP" or "MENU" buttons.
When an error occurs using the TrueFeed, the display will indicate an error code and description.
Together with the displayed error an output contact will be switched.
The controller itself gives a beeping signal and the alarm LED will illuminate.
To distinguish a Warning or Alarm:
Warning:
Warning output is ON, but the feeding unit continues running
(24VDC contact, pin 22-23 of the main board will be active,
for example to activate the alarm strobe)
Alarm:
Alarm output is ON and the feeding unit stops running
(Potential free contact, pins 26-27 of the main board will be active, for example to
stop the injection molding machine)
Free programmable errors can be configured to an Alarm or Warning.
For setting the free programmable outputs to an alarm or warning, enter the ALARMS menu.
First the alarm history will be shown. The alarms and warnings will be stored here.
When you press the "MENU" button again you will enter the alarm configuration menu.
Here you can set the alarm or warning output with
ALARM HISTORY
All alarms and warnings will be stored in the alarm history.
Go to the ALARMS <menu>
Press
to scroll to the stored alarms (max. 50).
The alarm history can be reset by the supervisor in CONFIGURATION <menu> by
Master reset: Alarm
Listed below are the following Errors:
Error
Code
Warnings
00
Low hopper level
01
Maximum deviation exceeded
02
Filling system unable to load material
03
Maximum RPM exceeded, change
dispensing cylinder for higher capacity
05
Calibration, no weight change
07
Minimum motor speed < 0.1 RPM
Alarms
08
Motor connection failure
09
Parameters damaged
10
Parameters set to factory defaults
11
Loadcell calibration set to factory defaults
13
Loadcell connection failure
14
UDP link error
15
Software version mismatch
and press "ENTER".
Material is below the hopper empty weight
The deviation of the material output is too high
Fill system is not working correctly
Calculated motor speed is too high
No weight change while calibrating
Calculated motor speed is too low
Motor not connected/Motor or connection damaged
Check configuration parameters
Check all parameter settings
Recalibrate the loadcell
Loadcell connection is not correct
No Ethernet connection between the Regrind and Color units
Software versions of the Regrind and Color units are different
31
Dual Feed TrueFeed Manual