4. With a slotted screwdriver, push in on the board support tabs, while
5. Remove any tubing connected to the circuit board (If applicable).
6. Remove the circuit board.
8.3.6.2
1. Push the circuit board onto the support tabs.
2. Firmly plug in the 10-pin connector.
3. Reconnect (If applicable) any tubing disconnected during the circuit
board removal procedure.
4. Reconnect the back and side panels.
8-12
you lift each corner of the circuit board.
Handle the new circuit board only by the edges to
prevent electrostatic damage to the unit.