The following procedure details how to assign the Wireless Controller to the Digital
Mixer Valve and test the remote signal strength.
Note! No plumbing connections are required for this test.
Note! Other radio signals from sources such as mobile phones, radios controlled
boiler thermostats, wireless broadband etc. can dramatically reduce the ability of
the Mira Platinum to register.
It is recommended that such items are switched off during this process.
Place the Digital Mixer Valve in the required location, no more than 10 m from
WKH ¿QDO SRVLWLRQ RI WKH :LUHOHVV &RQWUROOHU
Connect the Digital Mixer Valve to the electrical supply via a 3 amp fused
spur switch - DO NOT TURN ON.
Bring Wireless Controller to within approximately 1 m of the
Digital Mixer Valve. Fit 3 x AA batteries supplied.
Switch on electrical supply to Digital Mixer Valve.
The Digital mixer will now begin to make a noise as it resets itself and
registers with the Wireless Controller.
Droplet symbol is displayed for approximately 30 seconds.
Do not remove the batteries or switch off the Digital Mixer
Valve. Droplet symbol goes out indicating Digital Mixer Valve
and Wireless Controller have been assigned to each other.