If you experience any difficulty with the installation or operation of your new shower, then please refer to the Fault Diagnosis section, before contacting Kohler Mira Ltd. Our telephone and fax numbers can be found in the back of this guide.
Having done so, keep it handy for future reference. The Mira Vision Dual Mixer Valve is designed to be used with the Mira Vision showerhead and fittings. Products Covered by this Guide Mira Vision Dual Digital Mixer - High Pressure/Combi Valve Mira Vision Dual Digital Mixer - Pumped Valve.
1. THIS APPLIANCE MUST BE EARTHED. ENSURE SUPPLEMENTARY BONDING COMPLIES WITH THE “REQUIREMENTS FOR ELECTRICAL INSTALLATIONS”. The Mira Digital Mixer Valve is intended to be permanently connected to the fixed electrical wiring of the mains system. A means for electrical isolation of the appliance shall be provided in the fixed wiring in accordance with local wiring regulations.
Page 5
Caution! 1. Read all of these instructions and retain this guide for later use. 2. The electrical installation must comply to “BS 7671 - Requirements for Electrical Installations” commonly referred to as the IEE Wiring Regulations, or any particular regulations and practices, specified by the local electricity supply company.
PACK CONTENTS Tick the appropriate boxes to familiarise yourself with the part names and to confirm that the parts are included. Documentation 1 x Wireless Controller User Guide 1 x Showerhead User Guide 1 x Customer Support Brochure Digital Mixer Valve Digital Mixer - Digital Mixer - Pumped Valve High Pressure / Combi Valve...
Page 7
Ceiling Fed Fittings 1 x Plastic Pipe 2 x Ceiling Plate 1 x Deluge Head 1 x Ceiling Mount Plate 2 x Brackets 1 x Showerhead 2 x Elbow Kit 2 x Spacers 2 x Extension 1 x Brazed Pipe 1 x Slide Bar Assembly 1 x Ceiling Plate...
Page 8
Rear Fed Fittings 1 x Concealing Shroud 2 x Brackets 1 x Shower 1 x Showerhead 1 x Deluge Head 1 x Slide Bar Assembly 1 x Backplate Assembly 1 x Hose 2 x End Plugs 1 x Fittings Pack 2 x Rubber Washers 1 x Right Angle 1 x Right Angle...
SPECIFICATIONS Standards and Approvals The Mira Vision Dual complies with all relevant directives for CE marking. The Mira Vision Dual is a type 1 electronic, independently mounted control for surface mounting. The Mira Vision Dual is in compliance with the essential requirements of the R&TTE directive 1999/5/EC.
Page 10
Mira Digital Mixer Valve Pumped Pressures Maximum Static Pressure 100 kPa (1 bar) = 10 m max. total head Maximum Maintained Pressure 100 kPa (1 bar) = 10 m max. total head Minimum Maintained Pressure 1 kPa (0.01 bar) = 0.1 m min. total head...
MIN. SUPPLY PRESSURE: 50 kPa (0.5 bar) MAX. WORKING PRESSURE: 500 kPa (5 bar) MAX. STATIC PRESSURE: 1000 kPa (10 bar) (WRAS) MAX. SUPPLY WATER TEMP: 65 °C MOUNTING POSITION VERTICAL HORIZONTAL KOHLER MIRA LTD. CHELTENHAM GL52 5EP TEL: (+44) 0870 241 0888 www.mirashowers.co.uk COLD F14319/1...
Page 12
Shower Fittings - Slide Bar and Showerhead 150 mm 62 mm 645 mm Maximum to ceiling 82 mm Shower Fittings - Ceiling Fed Arm 60 mm Minimum 51 mm 600 mm Maximum 250 mm...
• Interference from other radio signals can dramatically reduce the ability of the Mira Vision User Interface / digital mixer to communicate. This may include; mobile phones, radio control boiler thermostats, wireless broadband routers, radio control toys, cordless phones, remote outdoor weather stations etc.
Page 14
MAX. WORKING PRESSURE: 500 kPa (5 bar) MAX. STATIC PRESSURE: 1000 kPa (10 bar) (WRAS) MAX. SUPPLY WATER TEMP: 65 °C MOUNTING POSITION VERTICAL HORIZONTAL KOHLER MIRA LTD. CHELTENHAM Mira Vision GL52 5EP TEL: (+44) 0870 241 0888 www.mirashowers.co.uk COLD...
A flow regulator may need to be used to ensure that the digital mixer valve can deliver a full range of water temperatures. The table indicates the flow regulator to be fitted in the hot water inlet of the Mira digital mixer valve.
Page 16
MIN. SUPPLY PRESSURE: 50 kPa (0.5 bar) MAX. WORKING PRESSURE: 500 kPa (5 bar) MAX. STATIC PRESSURE: 1000 kPa (10 bar) (WRAS) MAX. SUPPLY WATER TEMP: 65 °C MOUNTING POSITION KOHLER MIRA LTD. VERTICAL HORIZONTAL CHELTENHAM GL52 5EP TEL: (+44) 0870 241 0888 www.mirashowers.co.uk...
Page 17
PROTECTION: IP24 MIN. SUPPLY HEAD: 0.1 m (0.01 bar) MAX. WORKING HEAD: 10 m (1 bar) MAX. SUPPLY WATER TEMP: 65 °C MOUNTING POSITION VERTICAL HORIZONTAL KOHLER MIRA LTD. CHELTENHAM GL52 5EP TEL: (+44) 0870 241 0888 www.mirashowers.co.uk COLD F14318/1...
Page 18
Typical Examples of Poor Plumbing and Installation Practices DO NOT: • Install the Digital Mixer Valve where it can become frozen • Position the Digital Mixer Valve where maintenance access is poor • Install into a system where the cold water cistern holds less than 230 litres •...
Installation Schematic Cold Inlet 3 amp switched To Mains Digital Mixer fused spur Power Supply Valve Hot Inlet Dual Outlets Isolators Metal pipework must be earth bonded A separate, permanently connected supply must be taken from the ring main to the appliance through a 3 amp double pole switched fuse spur providing a minimum 3 mm contact separation gap in each pole.
Page 20
Long inlet pipework (dead-legs) should be kept to a minimum to avoid temperature fluctuations. Supply pipework layout must be arranged to minimize the effect of other outlet usage upon the dynamic pressures at the digital mixer valve inlets. To eliminate pipe debris it is essential that supply pipes are thoroughly flushed through before connection to the digital mixer valve.
MIN. SUPPLY PRESSURE: 50 kPa (0.5 bar) MAX. WORKING PRESSURE: 500 kPa (5 bar) MAX. STATIC PRESSURE: 1000 kPa (10 bar) (WRAS) MAX. SUPPLY WATER TEMP: 65 °C MOUNTING POSITION VERTICAL HORIZONTAL KOHLER MIRA LTD. CHELTENHAM GL52 5EP TEL: (+44) 0870 241 0888 www.mirashowers.co.uk COLD F14319/1...
Page 22
Fit 3 x AA batteries (supplied) into the wireless controller. Ensure the wireless controller LCD lights up then switch on power to the digital mixer valve. Depending on the type and version of your wireless controller, the software revision number (eg. r04) may be briefly displayed, the controller will then display its default time of 10:00.
Page 23
Drill and plug the fixing holes. Note! Installers may wish to use alternative cavity fixings, when installing onto a dry lined, stud partition, shower cubicle or laminated panel wall structures. However, these methods of fixing are beyond the scope of this guide.
Shower Fittings - Ceiling Fed Slide Bar / Showerhead Suitable for solid, dry-lined, stud partition, shower cubicle or laminated panel walls. The Slide Bar should be fixed to the wall at a convenient height for all the family. It should be positioned so that water sprays down the centre of the bath, or away from the opening of a shower cubicle.
Page 25
Drill and plug Slide Bar Assembly fixing holes. Insert fixing screws through holes in Wall Brackets and fix to wall. Do not fully tighten. Use template to set correct distances between Wall Brackets. Fully tighten screws. Use longer fixing screws if using spacers supplied.
Page 26
Fit Slide Bar Assembly over Wall Brackets and secure with screws supplied. Do not overtighten. Connect ceiling extension tube. Feed plastic pipe up through the slide bar and extension into ceiling. Do not allow any debris to block the plastic pipe. Note! If plastic pipe requires shortening, make sure there is enough length to fit elbow (supplied)
Place first washer in end of hose, then attach to pipe end. Do not fit showerhead until after pipework has been fully flushed through. Refer to section “Commissioning”. Ceiling Fed Deluge Head The Deluge Head should be fixed to the ceiling at a convenient height for all the family.
Page 28
Centralise the brazed pipe in the hole then screw the ceiling mount plate to the wooden support. Offer the deluge head to the brazed 30 mm pipe and determine the showering height required. Push / pull the brazed pipe using a twisting motion to adjust the height.
Page 29
Push the cut end of the chrome extension tube into the Ceiling Plate then slide the extension tube over the threaded end of the brazed pipe and up through the hole until the ceiling plate is secured in the hole and the ceiling plate is flat against Ceiling the ceiling.
Rear Fed Slide Bar / Showerhead Suitable for solid, dry-lined, stud partition, shower cubicle or laminated panel walls. The Slide Bar should be fixed to the wall at a convenient height for all the family. It should be positioned so that water sprays down the centre of the bath, or away from the opening of a shower cubicle.
Page 31
Insert fixing screws through holes in wall brackets and fix to wall. Do not fully tighten at this stage. Use template to set correct distances between wall brackets. Fully tighten screws. Note! Slots in wall brackets allow for adjustment. Use one horizontal slot and one vertical slot.
Page 32
The pipe work must protrude through the wall between 20 - 23 mm from the finished surface of the wall. If the pipe protrudes further than 23 mm, it will prevent the backplate nut from engaging with the backplate. If necessary cut the pipe to the correct length and remove any burrs.
Page 33
Place the backplate over the Backplate outlet pipe with the arrow pointing vertically up and tighten the two backplate screws. Make sure that Copper Pipe the foam seal abuts the finished wall surface. 2 x Screws Fit the olive and the backplate nut over the outlet pipe, do not tighten the nut fully at this point.
Rear Fed Shower Arm and Deluge Head The Shower Arm and Deluge Head should be fitted at a convenient height for all the family. It should be positioned so that water sprays down over the centre of the bath, or away from the opening of a shower cubicle. The outlet pipe must protrude 18 mm (±...
Page 35
Fit the olive and compression nipple Backplate over the outlet pipe and tighten the compression nipple. Compression Nipple Olive Fit the concealing shroud onto the shower arm. Fit the compression nut and olive onto the shower arm. Compression Olive Fit the shower arm into the compression nipple and tighten the compression nut.
Wireless Controller Suitable for solid, dry-lined, stud partition, shower cubicle or laminated panel walls. The wireless controller should be fixed to the wall at a convenient height for all the family. It should be positioned so that water does not spray over it when the Showerhead is held on the Slide Bar.
COMMISSIONING Turn on electrical supply to digital mixer valve. Make sure the end of the hose is in either the bath, shower tray or other water catchment area. Note! The overhead mounting will flow water when switched on (“ ” or “ ”) depending on the outlet plumbing configuration.
Run cold water through (approximately 2 minutes) and check entire installation for water leaks. Press “ ” to turn shower off. Fit the second hose washer and showerhead. Press “ ” to turn shower on. Test operation of shower by increasing/decreasing both temperature and flow controls.
Page 39
Ensure the wireless controller LCD lights up then switch on power to the digital mixer valve. Depending on the type and version of your wireless controller, the software revision number (eg. r04) may be briefly displayed, the controller will then display its default time of 4:00 (unregistered).
RE-REGISTERING The wireless controller has previously been registered to the digital mixer valve at the factory. If communication problems are encountered, a re-registering of the wireless controller may be required. A re-registering of the wireless controller must also be performed should the control PCB in the digital mixer valve be replaced.
Re-registering required. Refer to “Re-Registering”. Digital Mixer Valve failure. Contact Kohler Mira Ltd. Wireless Controller failure. Contact Kohler Mira Ltd. Radio frequency interference. E n s u r e a l l o t h e r r a d i o transmitting devices, including mobile phones, are switched off.
Page 42
Probable Cause Possible Remedy Symptoms Low or no water flow. 1. Wireless Controller. Out of range. Refer to “Out of Range”. 2. Digital Mixer Valve. No power to Digital Mixer Check electrical connection Valve. and supply. Isolators closed. Open isolators. Filters blocked.
Page 43
Temperature”. Not hot enough (combi-boiler). Appropriate flow regulators not Fit appropriate flow regulator. Refer to “Spare Parts”. fitted to system using combi- boiler - (HP). Continuous flow. Shower will Digital Mixer Valve failure. Contact Kohler Mira Ltd. not shut off.
Page 44
Symptoms Probable Cause Possible Remedy Shower runs for a short time Air is being sucked down The hot draw off pipe is (30 - 60 seconds) then flow the vent pipe. (Gravity fed positioned too high in relation reduces, splutters or stops. system).
MAINTENANCE General Read the section “Important Safety Information” first. Before replacing any parts ensure that the underlying cause of the malfunction has been resolved. If the shower is dismantled during installation or servicing then upon completion the product must be inspected to ensure there are no leaks. Warning! There are no user serviceable components beneath the cover of the appliance.
ACCESSORIES Genuine Mira accessories can be purchased direct from Customers Services (our contact details can be found on the back cover of this guide) or from approved stockists or merchants. Premium Shower Seat Mira Standard Grab Bars Shower Seat White/Chrome - 2.1731.001 300 mm - 2.1605.070 White - 2.1536.128...
DISPOSAL AND RECYCLING End of Product Life When this appliance has reached the end of its serviceable life, it should be disposed of in a safe manner, in accordance with current local authority recycling, or waste disposal policy. Batteries Spent batteries should not be disposed of with normal household waste. Contact your local authority for information on waste disposal and recycling.
The product must be installed and maintained in Spares and Accessories - We hold the largest accordance with the instructions given in this user stocks of genuine Mira spares and accessories. guide. Contact us for a price or visit our website to...